2008
DOI: 10.1016/j.jelechem.2007.09.027
|View full text |Cite
|
Sign up to set email alerts
|

Direct electrochemical oxidation of proteins at conductive diamond electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
37
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
8
2

Relationship

4
6

Authors

Journals

citations
Cited by 75 publications
(37 citation statements)
references
References 21 publications
0
37
0
Order By: Relevance
“…Similarly, using boron doped diamond electrode, native and denatured BSA could be distinguished. 219 , 220 Topal et al 220 showed oxidation signals of native and denatured macroglobulin at a gold electrode close to 0.7 V. However, a basal plane carbon electrode displayed poor ability to distinguish between these forms of HSA. 221 Using EPGE, a number of proteins were tested, showing much higher oxidation peaks in denatured than in their native forms.…”
Section: Protein Oxidation At Carbon and Other Solid Electrodesmentioning
confidence: 99%
“…Similarly, using boron doped diamond electrode, native and denatured BSA could be distinguished. 219 , 220 Topal et al 220 showed oxidation signals of native and denatured macroglobulin at a gold electrode close to 0.7 V. However, a basal plane carbon electrode displayed poor ability to distinguish between these forms of HSA. 221 Using EPGE, a number of proteins were tested, showing much higher oxidation peaks in denatured than in their native forms.…”
Section: Protein Oxidation At Carbon and Other Solid Electrodesmentioning
confidence: 99%
“…It was previously reported that Bovine Serum Albumin (BSA) are electroactive at hydrogen terminated BDD but not at oxidized terminated BDD electrodes. 38 Since the oxidized terminated one was employed in this work, it can be presumed that the oxidation peaks that appeared at the CVs were related to the oxidation of biotin-streptavidin systems. Furthermore, these peaks appeared at different potentials with very small currents in comparison with the thiocholine peak.…”
Section: Modification Of Magnetic Beads With Achementioning
confidence: 99%
“…This result is reasonable since mucin contains proteins, which can provide some electroactive functional groups. 34,35 The presence of mucin also seems to give current contributions as showed by higher slopes for both oxidation and reduction peak currents. However, a comparable LODs was achieved, i.e.…”
Section: Electrochemical Detection Of Neuraminidase (Na)mentioning
confidence: 99%