1995
DOI: 10.1093/clinchem/41.3.381
|View full text |Cite
|
Sign up to set email alerts
|

Direct enzyme-linked immunosorbent assay and a radioimmunoassay for melatonin compared

Abstract: A novel commercially available ELISA for direct measurement of melatonin concentration in serum was evaluated and compared with an RIA routinely used in our laboratory. The direct ELISA is technically simpler, requires a smaller sample volume (0.1 mL), and compares well with RIA in terms of stability of the calibration curve and intra- and interassay CVs. Correlation with RIA measurements is, however, suboptimal (y = 0.39x + 56; r = 0.65, P < 0.001; n = 138), which may be due to a serum effect, as evide… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

1999
1999
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…There are also numerous enzyme-linked immunoassay (ELISA) commercial kits used for the analysis of melatonin in urine, blood, and saliva. A commercial ELISA kit was compared to the RIA method: a purification step (not specified by the manufacturer) was necessary to obtain good correlations with RIA for monitoring human blood melatonin [ 125 ]. In this study, the ELISA method presented a mean inter-assay CV of 15.4%, but it is more convenient than RIA (no radioactive wastes).…”
Section: Measure Of Melatonin Concentrations Depending On the Typementioning
confidence: 99%
“…There are also numerous enzyme-linked immunoassay (ELISA) commercial kits used for the analysis of melatonin in urine, blood, and saliva. A commercial ELISA kit was compared to the RIA method: a purification step (not specified by the manufacturer) was necessary to obtain good correlations with RIA for monitoring human blood melatonin [ 125 ]. In this study, the ELISA method presented a mean inter-assay CV of 15.4%, but it is more convenient than RIA (no radioactive wastes).…”
Section: Measure Of Melatonin Concentrations Depending On the Typementioning
confidence: 99%
“…Direct melatonin immunoassays rely very heavily on the specificity of the antibody and the absence of any nonspecific matrix effects. In 1995, Chegini et al compared the performance of a direct ELISA and an extraction RIA using human plasma samples. The ELISA used a rabbit anti‐melatonin antibody purchased from Buhlmann Laboratories and peroxidase‐conjugated melatonin, while the RIA used antiserum purchased from CID‐Tech and chloroform extraction and a petroleum ether wash.…”
Section: Issues To Consider When Conducting Melatonin Studiesmentioning
confidence: 99%
“…Melatonin can be detected through several methods, such as radioimmunoassay (RIA) [13,[27][28][29], enzymelinked immunosorbent assay (ELISA) [28,[30][31][32] and highperformance liquid chromatography (HPLC) [19,33]. In order to increase the validity of results, determination of melatonin was performed successfully using mass spectrometry [34].…”
mentioning
confidence: 99%