2018
DOI: 10.1002/anie.201712306
|View full text |Cite
|
Sign up to set email alerts
|

Direct Measurement of Charge Regulation in Metalloprotein Electron Transfer

Abstract: Determining whether a protein regulates its net electrostatic charge during electron transfer (ET) will deepen our mechanistic understanding of how polypeptides tune rates and free energies of ET (e.g., by affecting reorganization energy, and/or redox potential). Charge regulation during ET has never been measured for proteins because few tools exist to measure the net charge of a folded protein in solution at different oxidation states. Herein, we used a niche analytical tool (protein charge ladders analyzed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
45
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 17 publications
(47 citation statements)
references
References 25 publications
(42 reference statements)
2
45
0
Order By: Relevance
“…For example, the accurate measurement of Z from the Gibbs–Donnan effect (through ultracentrifugation) requires milliliters of protein solution at high purity (>95 %), high protein concentration (near millimolar), and hours per experiment . In contrast, the capillary electrophoresis of a “protein charge ladder” requires nanoliters of protein solution, at micromolar concentration and <10 minutes per experiment …”
Section: Mass Spectrometer‐yes Charge Spectrometer‐nomentioning
confidence: 99%
See 4 more Smart Citations
“…For example, the accurate measurement of Z from the Gibbs–Donnan effect (through ultracentrifugation) requires milliliters of protein solution at high purity (>95 %), high protein concentration (near millimolar), and hours per experiment . In contrast, the capillary electrophoresis of a “protein charge ladder” requires nanoliters of protein solution, at micromolar concentration and <10 minutes per experiment …”
Section: Mass Spectrometer‐yes Charge Spectrometer‐nomentioning
confidence: 99%
“…The utility of “protein charge ladders” and their unique capabilities in determining protein net charge has been reviewed . These studies and others have shown that the effective net charge of a protein can be different in sign and magnitude (by >10 units) than values predicted from formal p K a values …”
Section: Mass Spectrometer‐yes Charge Spectrometer‐nomentioning
confidence: 99%
See 3 more Smart Citations