2012
DOI: 10.1016/j.actamat.2012.07.040
|View full text |Cite
|
Sign up to set email alerts
|

Direct measurement of large reversible magnetic-field-induced strain in Ni–Co–Mn–In metamagnetic shape memory alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
48
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 76 publications
(52 citation statements)
references
References 36 publications
4
48
0
Order By: Relevance
“…2.3(c). In quaternary systems such as Ni-Co-Mn-In [58,65,66,[97][98][99][100][101], Ni-Co-Mn-Sn [15,101,102], Ni-CoMn-Sb, [101,103,104], Ni-Co-Mn-Al [17,46,[105][106][107] and Ni-Co-Mn-Ga [16,[108][109][110], the same relationship of ΔM as well as MFIT have been found. It should be noted that in most of the above cited studies, magnetization was monitored for the detection of MFIT.…”
Section: Clausius-clapeyron Equationssupporting
confidence: 57%
See 2 more Smart Citations
“…2.3(c). In quaternary systems such as Ni-Co-Mn-In [58,65,66,[97][98][99][100][101], Ni-Co-Mn-Sn [15,101,102], Ni-CoMn-Sb, [101,103,104], Ni-Co-Mn-Al [17,46,[105][106][107] and Ni-Co-Mn-Ga [16,[108][109][110], the same relationship of ΔM as well as MFIT have been found. It should be noted that in most of the above cited studies, magnetization was monitored for the detection of MFIT.…”
Section: Clausius-clapeyron Equationssupporting
confidence: 57%
“…3(b). In Ni-Mn-based alloy systems, research studies have been done for Ni-Mn-Ga [62], Ni-CoMn-In [14,[63][64][65][66][67] single crystals and Ni-Co-Mn-In [68] and Ni-Co-Mn-Al [69] poly-crystals. On the other hand, this is the phenomenon attributable to the elastocaloric effect [70][71][72], which is of practical importance.…”
Section: Clausius-clapeyron Equationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The martensitic phase of these alloys is almost nonmagnetic; the application of a magnetic field induces a shift of MT to lower temperatures with a sensitivity of up to 10 K/T [9]. Further work is still needed to diminish the hysteresis of MT in order to use lower fields (H < 2 T) and to optimize the temperature range of the actuation.…”
Section: Experimental Descriptionmentioning
confidence: 99%
“…Recently the new metamagnetic Heusler functional alloys Ni-Mn-In-Co and Ni-Mn-Ga-Co have been a subject of intensive investigation [9,10]. The martensitic phase of these alloys is almost nonmagnetic; the application of a magnetic field induces a shift of MT to lower temperatures with a sensitivity of up to 10 K/T [9].…”
Section: Experimental Descriptionmentioning
confidence: 99%