Direct three-dimensional observation of the microstructure and chemistry of C3S hydration

Abstract: Disagreements about the mechanisms of cement hydration remain despite the fact that portland cement has been studied extensively for over 100 years. One reason for this is that direct observation of the change in microstructure and chemistry are challenging for many experimental techniques. This paper presents results from synchrotron nano X-ray tomography and fluorescence imaging. The data show unprecedented direct observations of small collections of C3S particles before and after different periods of hydrat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
39
0
5

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 60 publications
(47 citation statements)
references
References 64 publications
2
39
0
5
Order By: Relevance
“…Some sedimentation (bleeding) could occur in the sample with w/s = 5 during the experiment, but the results provide an average w/s that matches the nCT experiments. The details of these experiments are given in a previous publication [44]. …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Some sedimentation (bleeding) could occur in the sample with w/s = 5 during the experiment, but the results provide an average w/s that matches the nCT experiments. The details of these experiments are given in a previous publication [44]. …”
Section: Methodsmentioning
confidence: 99%
“…IPA was used because it has been suggested previously to have the least impact on the microstructure of hydrated samples [45,46]. Previous work with these same materials and techniques has indicated no observed differences in the microstructure before and after using IPA to stop hydration [44]. The cup was then lowered and the sample was placed back on the nCT scanner to obtain the final tomography scan.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experimental data reported in this paper have been published in a previous paper with full details on the procedures used [18]. A brief summary of the procedure is provided here.…”
Section: Methodsmentioning
confidence: 99%
“…The particles remained submerged for 7 h, after which the seal was removed and hydration arrested by solvent exchange with 99 % isopropyl alcohol (IPA) for 5 min. IPA was used because it has been shown previously to cause no observable differences in the C−S−H morphology or other aspects of the microstructure of hydrated specimens [18]. …”
Section: Methodsmentioning
confidence: 99%