2016
DOI: 10.1016/j.ijrobp.2016.06.015
|View full text |Cite
|
Sign up to set email alerts
|

Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary–Interstitial Techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
51
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 37 publications
(54 citation statements)
references
References 35 publications
2
51
0
Order By: Relevance
“…All cases were then reoptimized for both Con.T&R and DMBT&R to receive the same CTV HR D 90 . In total, 108 individual plans (8 shields × 12 clinical cases) with DMBT&R and 12 respective individual Con.T&R plans were re‐optimized with an in‐house code based on gradient projection convex optimization algorithm. The optimization process was previously described in detail .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…All cases were then reoptimized for both Con.T&R and DMBT&R to receive the same CTV HR D 90 . In total, 108 individual plans (8 shields × 12 clinical cases) with DMBT&R and 12 respective individual Con.T&R plans were re‐optimized with an in‐house code based on gradient projection convex optimization algorithm. The optimization process was previously described in detail .…”
Section: Methodsmentioning
confidence: 99%
“…Such would be helpful especially when the CTV HR is irregular/bulky in shape and extends beyond upper vagina away from the reaches of the ovoids/ring. Recognizing this apparent lag in tandem technology, a novel six‐channel MR‐compatible intrauterine tandem applicator is designed around an isotropic 192 Ir source based on the concept of direction modulated brachytherapy (DMBT) . This design is able to create directional radiation dose profile via intelligently designed tungsten shield leading to enhanced dose sculpting capacity for each individual CTV HR through inverse optimization.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…High-dose-rate (HDR) sources containing 153 Gd (9) or 192 Ir (10,11) with built-in shielding have been investigated, but current technology prohibits interstitial implantation due to the required shield thickness and resultant puncture diameter. A directional source is more readily achieved with a source having lower energy emissions and consequently a thinner shield.…”
Section: Introductionmentioning
confidence: 99%
“…Intensity modulated brachytherapy (IMBT) is a novel brachytherapy technique which incorporates static or dynamic shields inside needles or applicators to direct the radiation toward the tumor and away from healthy tissues. [15][16][17] IMBT has been investigated for prostate, [18][19][20] cervical, [21][22][23][24][25][26] and rectal cancers. 27,28 In the case of prostate cancer, IMBT has the capability to reduce the dose delivered to nearby radiation sensitive healthy tissues, such as the urethra, or allow for dose escalation without an associated increase in urethral dose for monotherapy.…”
Section: Introductionmentioning
confidence: 99%