2015
DOI: 10.1109/tpel.2014.2329452
|View full text |Cite
|
Sign up to set email alerts
|

Distortion-Free Saturators for Power Converters Under Unbalanced Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 39 publications
0
13
0
Order By: Relevance
“…It must be remarked that (11) does not need to be computed; the parallel implementation, (9) and (10), being used instead. Finally, the fraction of saturation voltage corresponding to each parallel controller must be calculated (14).…”
Section: B Efficient Implementationmentioning
confidence: 99%
See 2 more Smart Citations
“…It must be remarked that (11) does not need to be computed; the parallel implementation, (9) and (10), being used instead. Finally, the fraction of saturation voltage corresponding to each parallel controller must be calculated (14).…”
Section: B Efficient Implementationmentioning
confidence: 99%
“…However, this does not imply a correct harmonic compensation during the saturated state. As it was described in the introduction, several researchers [13], [14], [15], [16] have dealt with the problem of harmonic distortion during saturation. The use of the realizable references technique will further simplify the introduction of compensation mechanisms but the harmonic distortion will depend on the selection of the saturated complex vector.…”
Section: Saturation Strategiesmentioning
confidence: 99%
See 1 more Smart Citation
“…In the paper, the use of the distortion-free saturators based on stationary reference frames (SRFs) is proposed. In particular, the saturators proposed in [20]. The SRF saturators reduce the amplitude of the signal while maintaining the original waveform.…”
Section: Stationary Reference Saturatormentioning
confidence: 99%
“…In [17], using average and second harmonic components of real and reactive powers, grid-connected inverter current references are generated in SYRF to limit the fault current. Distortion-free saturation strategies for a three-phase threewire inverter are proposed in [18] in which the control system is implemented in SYRF while a similar procedure can be used for STRF case. In [19], a hardware-circuit-based hysteresis current control strategy is proposed to limit output currents of three-phase three-wire inverters in which the control system is implemented in SYRF.…”
Section: Introductionmentioning
confidence: 99%