2010
DOI: 10.1246/cl.2010.272
|View full text |Cite
|
Sign up to set email alerts
|

Distribution of Fluorescent Dyes Dissolved in Ternary Mixed Solvent in a Microchannel under Laminar Flow Conditions

Abstract: We observed chromatographic separation in an open capillary tube with a water–hydrophilic–hydrophobic organic mixture carrier solution. The separation is thought to be based on the tube radial distrubution of aqueous and organic carrier solvents in the capillary tube. In this study, in order to obtain information concerning the solvent distribution, we delivered a carrier solution containing fluorescent dyes into a microchannel (100 µm in width × 40 µm in depth) and monitored the tube radial distribution of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
26
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 13 publications
(27 citation statements)
references
References 5 publications
1
26
0
Order By: Relevance
“…[16][17][18][19][20][21][22][23] Here, instead of acetonitrile (hydrophilic organic solvent), methanol, ethanol, 1,4-dioxane, and 1-propanol were used to prepare the homogeneous ternary mixed carrier solutions that had the specific component ratios of the solvents near the homogeneous-heterogeneous solution boundary region. The component ratios of the solvents in thus prepared carrier solutions were as follows: water-methanol-ethyl acetate (100:20:15 volume ratio), water-ethanol-ethyl acetate (100:20:15 volume ratio), water-1,4-dioxane-ethyl acetate (100:5:10 volume ratio), and water-1-propanol-ethyl acetate (100:10:11 volume ratio).…”
Section: Chromatograms Obtained With the Carrier Solutions Using Varimentioning
confidence: 99%
See 2 more Smart Citations
“…[16][17][18][19][20][21][22][23] Here, instead of acetonitrile (hydrophilic organic solvent), methanol, ethanol, 1,4-dioxane, and 1-propanol were used to prepare the homogeneous ternary mixed carrier solutions that had the specific component ratios of the solvents near the homogeneous-heterogeneous solution boundary region. The component ratios of the solvents in thus prepared carrier solutions were as follows: water-methanol-ethyl acetate (100:20:15 volume ratio), water-ethanol-ethyl acetate (100:20:15 volume ratio), water-1,4-dioxane-ethyl acetate (100:5:10 volume ratio), and water-1-propanol-ethyl acetate (100:10:11 volume ratio).…”
Section: Chromatograms Obtained With the Carrier Solutions Using Varimentioning
confidence: 99%
“…Here, instead of ethyl acetate (hydrophobic organic solvent) in the ternary mixture carrier solution of water-acetonitrile-ethyl acetate as in our previous reports, [16][17][18][19][20][21][22][23] chloroform, hexane, and 1-butanol were used to prepare the homogeneous ternary mixed carrier solutions that had the specific component ratios of the solvents near the homogeneous-heterogeneous solution boundary region. The component ratios of the carrier solutions were as follows: water-acetonitrile-hexane (100:30:1 volume ratio), water-acetonitrile-chloroform (100:30:1 volume ratio), and water-acetonitrile-1-butanol (100:15:20 volume ratio).…”
Section: Chromatograms Obtained With the Carrier Solutions Using Varimentioning
confidence: 99%
See 1 more Smart Citation
“…1) is also drawn based on data of the fluorescence photographs and profiles obtained by a fluorescence microscope-CCD camera. 34 Since our investigation of the TRDC system has just begun, it is important to examine the elution behavior under various analytical conditions in the system in order to expand our knowledge regarding its separation performance. In this study, we examined the analytical conditions of the TRDC system in detail, including tube temperature, tube inner diameter, tube length, and flow rate using fused-silica capillary tubes and a water-acetonitrile-ethyl acetate mixture as a carrier solution.…”
Section: Introductionmentioning
confidence: 99%
“…Related research has been discussed in detail in our previous papers [6,7]. We have developed a capillary chromatography system using an open capillary tube and a water-hydrophilic/hydrophobic organic mixture carrier solution [6][7][8][9][10][11]. This system works …”
mentioning
confidence: 99%