Order By: Relevance
“…compared GNEE on basal-plane graphite modified electrode with GNEE on glassy carbon and macro gold electrode and found that the former had higher sensitivity(Dai and Compton 2005) Mardegan et al, (2012). reported a detection limit of 0.005µg/L with gold nano electrode ensemble (Au-NEE)(Mardegan et al 2012) Kamenev et al, (2001). reported graphite electrodes modified with gold and copper with detection limit of 17µg/L and 47µg/L respectively(Kamenev et al 2001), whereas a better detection limit (7µg/L) was obtained with gold-graphite electrode(Kamenev et al 2005) Beinrohr (2001)(Beinrohr 2001).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…compared GNEE on basal-plane graphite modified electrode with GNEE on glassy carbon and macro gold electrode and found that the former had higher sensitivity(Dai and Compton 2005) Mardegan et al, (2012). reported a detection limit of 0.005µg/L with gold nano electrode ensemble (Au-NEE)(Mardegan et al 2012) Kamenev et al, (2001). reported graphite electrodes modified with gold and copper with detection limit of 17µg/L and 47µg/L respectively(Kamenev et al 2001), whereas a better detection limit (7µg/L) was obtained with gold-graphite electrode(Kamenev et al 2005) Beinrohr (2001)(Beinrohr 2001).…”
mentioning
confidence: 99%
“…reported a detection limit of 0.005µg/L with gold nano electrode ensemble (Au-NEE)(Mardegan et al 2012) Kamenev et al, (2001). reported graphite electrodes modified with gold and copper with detection limit of 17µg/L and 47µg/L respectively(Kamenev et al 2001), whereas a better detection limit (7µg/L) was obtained with gold-graphite electrode(Kamenev et al 2005) Beinrohr (2001)(Beinrohr 2001). andLastincova et al, (2004)(Laštincová et al 2004) used gold coated porous working electrodes in stripping analysis of As(III) with flow through coulometry (FTC) method and reported detection limit of 0.17µg/L and 0.15µg/L respectively Umasankar et al, (2008).…”
mentioning
confidence: 99%
“…( and Au-coated carbon electrodes (graphite 2,7, 20,21 and glassy carbon [22][23][24] ). The metal's toxicity and the limited solubility of As make Hg less useful for this method.…”
mentioning
confidence: 99%
“…Alternativamente, filmes de Cu ou Hg podem ser depositados in situ sobre o eletrodo de carbono vítreo antes da redução de As(III) 80 . Em eletrodos de grafite pirolítico, a deposição de Cu(II) pode ser também empregada para a modificação da superfície do eletrodo como etapa preliminar à deposição de As(III) 81 . Técnicas voltamétricas de redissolução anódica para arsênio utilizando o eletrodo de mercúrio são impraticáveis do ponto de vista analítico, devido à interferência causada pela onda de oxidação do mercúrio durante a varredura anódica do potencial 62 .…”
Section: Determinação De Arsênio Por Asvunclassified