2012
DOI: 10.1016/j.joen.2011.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Does a Combination of Two Radiographs Increase Accuracy in Detecting Acid-induced Periapical Lesions and Does It Approach the Accuracy of Cone-Beam Computed Tomography Scanning?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
23
0
4

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 40 publications
(29 citation statements)
references
References 33 publications
2
23
0
4
Order By: Relevance
“…Several clinical studies had similar findings, although with slightly different percentages (9,10). Ex vivo experiments in which simulated periapical lesions were created yielded similar results (11,12). Results of in vivo animal studies, using histologic assessments as the gold standard also showed similar results observed in human clinical and ex-vivo studies (13).…”
mentioning
confidence: 60%
“…Several clinical studies had similar findings, although with slightly different percentages (9,10). Ex vivo experiments in which simulated periapical lesions were created yielded similar results (11,12). Results of in vivo animal studies, using histologic assessments as the gold standard also showed similar results observed in human clinical and ex-vivo studies (13).…”
mentioning
confidence: 60%
“…In a number of clinical studies 2,[16][17] , one to three observers analyzed the CBCT images and found that there was no significant difference between intra-and inter-observer measurements.…”
Section: Discussionmentioning
confidence: 99%
“…CBCT may be recommended for detecting AP where there is some clinical suspicion though not identified in periapical radiographs 17 . This study did not monitor the history, evolution and healing of the AP nor was any histological evaluation conducted, these being the limitations of the study when compared to the studies of Garcia de Paula-Silva et al 4 , Wu et al 23 and Jorge et al 30 .…”
Section: Discussionmentioning
confidence: 99%
“…This procedure made simulated initial lesions look like those observed in vivo, thereby enabling simulation of incipient lesions, which are more difficult to detect. 11,12,13,19 The anatomical proximity between the root apex and the cortical air space is more relevant than the size of a periapical lesion in establishing OAC. 3,8 Therefore, the longer acid etching time was not a Table 3.…”
Section: 34mentioning
confidence: 99%