Image quality of storage phosphor images was subjectively as good as conventional film images and superior to LCBCT images for the evaluation of both homogeneity and length of root fillings in single-rooted teeth.
Perceived image quality of the enhanced Digora images was superior to the original Digora and conventional film images for the evaluation of root fillings. However, E-speed film provided a significantly better image clarity in comparison with F-speed and original Digora images.
Objective: The aim of this study was to determine (1) the effect of various scan delays on pixel intensity measurements and (2) the diagnostic accuracy of occlusal caries detection. Methods: 72 non-cavitated extracted human permanent molar teeth with sound and carious occlusal surfaces were radiographed using the DIGORAH storage phosphor plates (SPPs) (Soredex Corporation, Helsinki, Finland). Plates were scanned immediately and 10 min, 30 min, 60 min and 120 min after exposure. Three different plates were used for each scan delay. An aluminium (Al) wedge was used to evaluate the change in mean grey values (MGVs) for scan delays. Diagnostic accuracy for occlusal caries detection was performed by scoring all the digital images. The true presence of caries was determined by stereomicroscopy. Comparison of MGVs of the Al wedge for immediate and delayed scans was made using repeated measures analysis of variance (ANOVA) and Tukey-Kramer tests. The accuracy was expressed as the area under the receiver operating characteristics curves (A z ). A z s were compared using two-way ANOVA and t-tests. Kappa was used to measure inter and intraobserver agreement. Results: The mean A z s of immediately scanned plates were higher than the A z s of plates scanned with four different delays (p , 0.05). The A z of immediately scanned images was significantly higher than the A z s of images with 60 min and 120 min scan delays (p , 0.05) but not for 10 min and 30 min delays (p . 0.05). MGVs of immediately scanned plates were significantly higher than the plates scanned with four different delays (p , 0.05). Agreement decreased with increasing scan delays. Conclusion: Scanning of DIGORA SPPs should not be delayed beyond 30 min for accurate occlusal caries diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.