2015
DOI: 10.1016/j.clinbiomech.2015.05.015
|View full text |Cite
|
Sign up to set email alerts
|

Does long-distance walking improve or deteriorate walking stability of transtibial amputees?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
22
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 20 publications
(25 citation statements)
references
References 42 publications
1
22
2
Order By: Relevance
“…Furthermore, the force sensors put at the left and right foot could also help distinguish the plantar force distribution of the affected and sound sides. This makes the plantar force sensors a suitable option for patients with stroke, as well as amputees [ 123 ], who commonly have different conditions regarding the sound and affected sides [ 124 ].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the force sensors put at the left and right foot could also help distinguish the plantar force distribution of the affected and sound sides. This makes the plantar force sensors a suitable option for patients with stroke, as well as amputees [ 123 ], who commonly have different conditions regarding the sound and affected sides [ 124 ].…”
Section: Discussionmentioning
confidence: 99%
“…Fatigue and learning effects were not accounted for in any included study. Tiredness is known to affect gait patterns in amputee walking [ 49 , 50 ], and the studies presented describe extensive testing procedures with multiple recorded trials and numerous perturbations of socket conditions. Although the impact is mitigated somewhat by randomising the order of induced perturbations between participants, there will still be a residual impact in the ability to acclimatise to new conditions and in the comparison to the original ‘neutral’ alignment.…”
Section: Discussion Of Study Qualitymentioning
confidence: 99%
“…To understand the underlying mechanism of this injury better, the application of EMG, ultrasound imaging techniques, and near-infrared spectroscopy are necessary to monitor the changes in cross-section area and activity during lunges for muscles and other soft tissue ( Chen et al, 2019a ; Guo et al, 2010 ). While muscle fatigue could implicate the risk of injury, a variability analysis on inter-limb coordination is useful to evaluate the instability induced by muscle fatigue ( Robertson et al, 2013 ; Hamill et al, 1999 ), despite the findings from some articles that the compensatory walking mechanisms against fatigue may interfere the analysis ( Wong, Lam & Lee, 2020 ; Wong et al, 2015 ). In addition, muscle fatigue could be measured by near-infrared spectroscopy studying the hemodynamic changes ( Tan et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%