Dose uncertainty and resolution of polymer gel dosimetry using an MRI guided radiation therapy system’s onboard 0.35 T scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 27 publications
1
9
0
Order By: Relevance
“…The strong magnetic field of the MRI subunit on MR-Linacs has an influence on the performance of many dosimeters. Studies were conducted to investigate the possible influence of the magnetic field on the dose response of 3D dosimeters and to gain confidence on the useability of an MR-Linac system on polymer gel dosimeters [ 93 , 395 , 396 , 397 , 398 ], radiochromic dosimeters [ 197 , 199 ] and Fricke gel dosimeters [ 399 ]. No detectable effect of the magnetic field on the dose-response was found in any of the 3D dosimeters.…”
Section: Towards 4d Radiation Dosimetrymentioning
confidence: 99%
“…The strong magnetic field of the MRI subunit on MR-Linacs has an influence on the performance of many dosimeters. Studies were conducted to investigate the possible influence of the magnetic field on the dose response of 3D dosimeters and to gain confidence on the useability of an MR-Linac system on polymer gel dosimeters [ 93 , 395 , 396 , 397 , 398 ], radiochromic dosimeters [ 197 , 199 ] and Fricke gel dosimeters [ 399 ]. No detectable effect of the magnetic field on the dose-response was found in any of the 3D dosimeters.…”
Section: Towards 4d Radiation Dosimetrymentioning
confidence: 99%
“…Another application of qMRI in RT could be real‐time visualization of biological dose. Because radiation dosimetry can be assessed in vitro using Bang gels, one can envisage extension to in vivo applications 135 . Through a deeper understanding of the short‐term effects of dose on tissue, we may find an MRI contrast mechanism, such as CEST or DWI, is sensitive to the short‐term biological effect of the treatment beam.…”
Section: Quantitative Mrimentioning
confidence: 99%
“…The readout techniques used in gel dosimetry have a great influence on their final application; in most cases, the available analytical methods in clinical facilities are favored. Thus, efforts have been made during the last few decades to apply MRI [ 60 , 61 ] and even use onboard MRI scanners included in modern MRI-based IGRT [ 62 ], X-ray computed tomography (CT) [ 58 , 63 , 64 ], or optical computed tomography methods (OCT) [ 65 , 66 , 67 ] to deliver 3D response distributions in gel dosimetry systems in clinical applications. Raman spectroscopy represents another technique widely used in gel dosimetry, but mainly for research purposes, as it provides quantitative information on the consumption of each reactive species without modifying the dosimeters and is capable of obtaining 2D distributions and even 3D distribution at the microscale [ 68 , 69 , 70 ].…”
Section: Readout Techniquesmentioning
confidence: 99%