2014
DOI: 10.1016/j.meddos.2013.09.004
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric difference amongst 3 techniques: TomoTherapy, sliding-window intensity-modulated radiotherapy (IMRT), and RapidArc radiotherapy in the treatment of late-stage nasopharyngeal carcinoma (NPC)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

10
35
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(46 citation statements)
references
References 19 publications
10
35
1
Order By: Relevance
“…24 Optimization of radiation treatment planning can help reduce mucositis and nausea by minimizing the dose to the mucosal surface and brainstem. 22, 25 As observed in our study, there is a trend toward enlarged setup errors with increasing number of fractions. The use of a shorter radiation treatment course with altered fractionation scheme may also help reduce setup errors.…”
Section: Discussionsupporting
confidence: 82%
“…24 Optimization of radiation treatment planning can help reduce mucositis and nausea by minimizing the dose to the mucosal surface and brainstem. 22, 25 As observed in our study, there is a trend toward enlarged setup errors with increasing number of fractions. The use of a shorter radiation treatment course with altered fractionation scheme may also help reduce setup errors.…”
Section: Discussionsupporting
confidence: 82%
“…FF-IMRT and VAMT contribute greatly in radiotherapy, followed by HT, a neo-CT based rotational IMRT, which provides better OARs sparing with 51 independent beam directions, delivers a highly conformal dose distribution. Nowadays, HT is frequently used for a variety of diseases [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…It has been indicated that given the same target dose coverage, VMAT is able to treat NPC more efficiently with less damage to OARs. 11,24 Ning et al 13 compared VMAT with IMRT for NPC treatment. They found that VMAT offered better protection to the OARs, particularly the temporal lobe, brain stem and parotid glands than IMRT.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with standard IMRT, VMAT can provide more precise conformal dose distribution through modulated gantry rotation speed, dose rate (DR) and multileaf collimator (MLC) pattern in linear accelerator. 10,11 Some studies have demonstrated that VMAT provide superior OARs/target coverage and fewer monitor units (MUs) per fraction over conventional IMRT for NPC. 12,13 However, few publications focused on the protection of hearing apparatus have been reported to compare between the two techniques.…”
Section: Introductionmentioning
confidence: 99%