2021
DOI: 10.1080/01902148.2021.1979693
|View full text |Cite
|
Sign up to set email alerts
|

Double-chamber plethysmography versus oscillometry to detect baseline airflow obstruction in a model of asthma in two mouse strains

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
7
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 49 publications
2
7
1
Order By: Relevance
“…It was characterized by increases in lung elastance ( H ) and tissue resistance ( G ). These results might appear inconsistent with our previous study (Boucher, Henry, Khadangi et al., 2021 ), in which only H was sightly but significantly increased by asthma in female mice. These inconsistencies are attributed to the presence (vs. the absence) of deep inflations before the measurement of respiratory mechanics.…”
Section: Discussioncontrasting
confidence: 99%
See 2 more Smart Citations
“…It was characterized by increases in lung elastance ( H ) and tissue resistance ( G ). These results might appear inconsistent with our previous study (Boucher, Henry, Khadangi et al., 2021 ), in which only H was sightly but significantly increased by asthma in female mice. These inconsistencies are attributed to the presence (vs. the absence) of deep inflations before the measurement of respiratory mechanics.…”
Section: Discussioncontrasting
confidence: 99%
“…Mice of each sex were divided into two groups of 20 (Figure 1 ): one group exposed to 25 μL of saline (control mice) and one group exposed to 25 μL of 2 mg of house dust mite (HDM) extract ( Dermatophagoides pteronyssinus ; Greer, Lenoir, NC, USA) per millilitre of saline to induce pulmonary allergic inflammation (asthmatic mice) (Boucher, Henry, Dufour‐Mailhot et al., 2021 , 2021 ; Sahu et al., 2010 ). The endotoxin concentration was 47.3 EU per milligram of HDM extract.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This can be epitomized by comparing elastance and volume between the lung of humans and mice. The elastance of a human lung (~ 0.005 cmH 2 O/mL), is about 3.7 logs inferior to a mouse lung (~ 30 cmH 2 O/mL) 8 , 15 , mainly because it is also about 3.7 logs bigger (6000 vs. 1 mL).…”
Section: Introductionmentioning
confidence: 91%
“…Interestingly, the elastance of the respiratory system is markedly greater in C57BL/6 than BALB/c mice 8 14 . The increased elastance of C57BL/6 versus BALB/c mice is also observed in open-chest conditions ( i.e.…”
Section: Introductionmentioning
confidence: 99%