2017
DOI: 10.1016/j.jpba.2017.08.041
|View full text |Cite
|
Sign up to set email alerts
|

Double-Track Electrochemical Green Approach for Simultaneous Dissolution Profiling of Naproxen Sodium and Diphenhydramine Hydrochloride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…Various analytical techniques have been exploited to DIPH determination either in single or mixture forms in pharmaceutical formulations and biological fluids including chromatography [9][10][11], spectrophotometry [12][13][14], capillary electrophoresis [15][16][17], and voltammetry [18,19]. Yet few ion selective electrodes potentiometric methods are reported [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…Various analytical techniques have been exploited to DIPH determination either in single or mixture forms in pharmaceutical formulations and biological fluids including chromatography [9][10][11], spectrophotometry [12][13][14], capillary electrophoresis [15][16][17], and voltammetry [18,19]. Yet few ion selective electrodes potentiometric methods are reported [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5] Dissolution testing is a vital analytical tool that is either used in quality control to ensure batch to batch uniformity or in research and development laboratories to predict the in vivo performance of orally administered solid formulations. [6][7][8][9][10] For this purpose, several dissolution media have been introduced as a tool for in vitro biorelevant dissolution. These media compositions approximately resemble both the pre-and postprandial states in the stomach and the upper small intestine aiming to approach the physiological condition regarding parameters such as pH, surface tension, buffer capacity, osmolality and viscosity.…”
mentioning
confidence: 99%
“…In addition, ISEs allowed the simultaneous monitoring of the dissolution profiles of the active substances present in the formulation through in-line potentiometric sensing. 3 Furthermore, ISEs opened more avenues for many possible pharmaceutical applications including in vivo unraveling of the possible kinetics of biological substances degradation and profiling of impurities present in APIs either from degradation or synthesis process. 4,5 However, there have been several shortage points which limit their application including the sensitivity to evaporation of their inner filling solutions, delamination or perforation of the ion sensing membrane and a need to cautious handling and maintenance.…”
mentioning
confidence: 99%