1978
DOI: 10.1021/ac50025a016
|View full text |Cite
|
Sign up to set email alerts
|

Dual-beam Fourier transform infrared spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
20
0

Year Published

1980
1980
2019
2019

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(20 citation statements)
references
References 5 publications
0
20
0
Order By: Relevance
“…The authors used the Kretchmann's ATR technique to observe the surface enhanced IR absorption (SEIRA) phenomenon but it is has been observed also in the transmission and external reflection geometries [3,4]. Since IR spectra of a small amount of molecules (pg~ tg) are obtained in good signal-to-noise ratios, the SEIRA spectroscopy is promising as a new trace analytical technique [4,5]. Unfortunately, however, its mechanism has not yet been understood.…”
mentioning
confidence: 99%
“…The authors used the Kretchmann's ATR technique to observe the surface enhanced IR absorption (SEIRA) phenomenon but it is has been observed also in the transmission and external reflection geometries [3,4]. Since IR spectra of a small amount of molecules (pg~ tg) are obtained in good signal-to-noise ratios, the SEIRA spectroscopy is promising as a new trace analytical technique [4,5]. Unfortunately, however, its mechanism has not yet been understood.…”
mentioning
confidence: 99%
“…He utilized both the interferogram and the anti-interferogram beam produced by an FTIR spectrometer and measured the resulting difference signal with a balanced detector. Later works inserted a reference and a sample into each beam and focused both outputs on a single detector [2,3], which results in the cancellation of the common AC-components of the opposing interferograms. In doing so, the effect of excess source noise on the detection limit can be in principle suppressed down to the shot-noise level of the source [4].…”
Section: Introductionmentioning
confidence: 99%
“…Because sequential measurements of sample and reference signal become unnecessary, the measurement time and systematic errors are reduced and the dynamic range requirements of the digitization electronics are relaxed [5]. However, none of the various dual-beam FTIR schemes [1][2][3][4][5][6], addressed the issue of the limited dynamic range of the detector because the DC-component of the interferograms was always present. In contrast, optically subtracting a reference signal before detection spatially isolates the sought-for signal, disclosing it in front of a quasi-zero background.…”
Section: Introductionmentioning
confidence: 99%
“…1,2 A photoconductive (PC) type HgCdTe (MCT) detector is the typical high sensitive IR detector well installed for versatile FTIR spectrometers according These improvements owe to two nominal merits of a FTIR spectrometer.…”
Section: Introductionmentioning
confidence: 99%