2019
DOI: 10.1109/tie.2018.2829678
|View full text |Cite
|
Sign up to set email alerts
|

Dual Role CDSC-Based Dual Vector Control for Effective Operation of DVR With Harmonic Mitigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…The state-space average modeling of the non-inverting operation is developed in (7) by adding the right-hand side of (5) and (6).…”
Section: A Dynamic Modeling During Non-inverting Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…The state-space average modeling of the non-inverting operation is developed in (7) by adding the right-hand side of (5) and (6).…”
Section: A Dynamic Modeling During Non-inverting Operationmentioning
confidence: 99%
“…caused by the rapid and uneven load distribution [5], [6]. The causes of power system disturbances can be split into three categories: the one is related to characteristics of the renewable resources; the second one is associated with solidstate electronic devices; the third one is linked with the reactive power demand.…”
Section: Introductionmentioning
confidence: 99%
“…There have been the various type of control techniques developed for controlling DVR for compensating PQ issues in recent times [11][12][13][14][15]. A symmetrical component estimation method of control has been implemented on DVR to compensate the voltage disturbances in the supply voltage [11].…”
Section: Introductionmentioning
confidence: 99%
“…Roldan-Perez et al in [13] have proposed a repetitive control method for improving the steady-state performance in DVR while addressing the voltage sag. Karthikeyan et al in [14] have developed cascaded delay signalbased pre-filter for extraction of symmetrical components from the disturbed voltage supply voltage to generate the DVR reference voltage.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, fractional differential equations have been considered greatly by research community in various aspects due to its salient features for real world problems (see [1][2][3][4][5][6][7]). Controllability problems for different kinds of dynamical systems have been studied by several authors (see [8][9][10][11][12][13][14][15]) and references therein.…”
Section: Introductionmentioning
confidence: 99%