2014
DOI: 10.1109/tpwrd.2014.2340870
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Average-Value Modeling of CIGRE HVDC Benchmark System

Abstract: High-voltage direct-current (HVDC) systems play an important role in modern energy grids, whereas efficient and accurate models are often needed for system-level studies. Due to the inherent switching in HVDC converters, the detailed switch-level models are computationally expensive for the simulation of large-signal transients and hard to linearize for small-signal frequency-domain characterization. In this paper, a dynamic average-value model (AVM) of the first CIGRE HVDC benchmark system is developed in a s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(29 citation statements)
references
References 24 publications
0
24
0
Order By: Relevance
“…This paper focuses on the abnormal condition that arise in an HVDC system in the event of commutation failure; i.e., when the extinction angle γ falls below γ min or where µ exceeds 60 • [18][19][20][21]. If µ exceeds 60 • , the subsequent commutation (i.e., from Valve 1 to Valve 3) will commence before completion of the current commutation (i.e., from Valve 2 to Valve 6).…”
Section: Equation Conversionmentioning
confidence: 99%
See 1 more Smart Citation
“…This paper focuses on the abnormal condition that arise in an HVDC system in the event of commutation failure; i.e., when the extinction angle γ falls below γ min or where µ exceeds 60 • [18][19][20][21]. If µ exceeds 60 • , the subsequent commutation (i.e., from Valve 1 to Valve 3) will commence before completion of the current commutation (i.e., from Valve 2 to Valve 6).…”
Section: Equation Conversionmentioning
confidence: 99%
“…In particular, power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC, or simply PSCAD) and MATLAB/SIMULINK have been used to elaborate the control schemes of CIGRE HVDC benchmark system models [21][22][23]. However, the AC network models used in these studies were simplified by using voltage sources and equivalent impedances, primarily because of the models' limited ability to model complex, large-scale AC networks.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, LCC offers higher conversion efficiency and proven reliability up to ultra-high voltage (UHV) applications compared to the VSC solutions using self-commutated switches. Therefore, it remains dominant in the construction of large-scale converter station for UHVDC links [7][8][9]. The compensation strategies for improving the commutation and reactive power performances of LCC can be implemented by using controlled capacitors or VSCs [10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Though a HVDC grid has many advantages, there are challenges that HVDC grid researchers need to face and deal with, such as how to control power flow and direct voltage and how to achieve fast control and protections. Currently, the researchers around world are undertaking HVDC grids related R&D work with their own models which are of different configurations and data [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%