1983
DOI: 10.1109/mper.1983.5518925
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Thermal Line Ratings, Part II - Conductor Temperature Sensor and Laboratory Field Test Evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Research continued with the group of Foss, Lin and Maraio at General Electric (USA) [21][22][23]10] who in the years 1983-1992 further developed the models and studied their dependence on each variable. Foss and Maraio [23] also reports the results of one of the first monitoring campaigns of the temperature of different points on an overhead line, and proposes the first method for DLR forecasting based on weather forecasts.…”
Section: Historical and Practical Perspectivesmentioning
confidence: 99%
“…Research continued with the group of Foss, Lin and Maraio at General Electric (USA) [21][22][23]10] who in the years 1983-1992 further developed the models and studied their dependence on each variable. Foss and Maraio [23] also reports the results of one of the first monitoring campaigns of the temperature of different points on an overhead line, and proposes the first method for DLR forecasting based on weather forecasts.…”
Section: Historical and Practical Perspectivesmentioning
confidence: 99%
“…The first commercial system based on conductor temperature monitoring, the Power Donut, was developed in the early eighties [7][8]. Besides monitoring the conductor temperature, the Power Donut monitors the current intensity.…”
Section: Conductor Temperature Monitoring Systemsmentioning
confidence: 99%
“…The conductor temperature can be measured directly [7][8][9][10] or it can be obtained indirectly from other magnitudes such as the conductor tension [11][12][13][14][15] or the sag [16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…Methods based on weather measurements [14] or conductor temperature monitoring [15,16] have been used. However, due to the uncertainties of these methods, modern methods are based on either tension [17,18] or sag [19] measurements.…”
Section: Real Time Monitoringmentioning
confidence: 99%
“…Examples that correspond to different countries, such as Spain [14], USA [15,[17][18][19], Japan [16], New Zealand [17,18] and Denmark [18] are shown.…”
Section: Real Time Monitoringmentioning
confidence: 99%