2017
DOI: 10.1016/j.ijepes.2017.04.003
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic thermal model of kiosk oil immersed transformers based on the thermal buoyancy driven air flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 5 publications
0
12
0
2
Order By: Relevance
“…Es importante acotar que en trabajos similares desarrollados anteriormente, también se han utilizado metodologías experimentales de este tipo para la validación de modelos térmicos, tal es el caso de los transformadores de distribución encapsulados con ventilación natural (Radakovic, 2017). En la Tabla 3 se pueden observar los datos de entrada utilizados para la estimación de temperatura en los modelos.…”
Section: Evaluación Y Clasificación Según Su Precisión Y Criterio De unclassified
“…Es importante acotar que en trabajos similares desarrollados anteriormente, también se han utilizado metodologías experimentales de este tipo para la validación de modelos térmicos, tal es el caso de los transformadores de distribución encapsulados con ventilación natural (Radakovic, 2017). En la Tabla 3 se pueden observar los datos de entrada utilizados para la estimación de temperatura en los modelos.…”
Section: Evaluación Y Clasificación Según Su Precisión Y Criterio De unclassified
“…Also, there is an approximation in the model for heat transfer along the radiators, which is important for the air buoyancy in the zone of the radiators. The basics about the buoyancy can be found in our previous publications [5] and [14]. Several improvements of the lumped model from [5] have been made in the meantime and will be published as an upgraded model for calculation of air buoyancy, based on the radiator modeled as a heat exchanger.…”
Section: Assumptions In the Modelmentioning
confidence: 99%
“…The basics about the buoyancy can be found in our previous publications [5] and [14]. Several improvements of the lumped model from [5] have been made in the meantime and will be published as an upgraded model for calculation of air buoyancy, based on the radiator modeled as a heat exchanger. In FEM CFD, fins are initially modeled as the rectangular aluminum bars.…”
Section: Assumptions In the Modelmentioning
confidence: 99%
See 2 more Smart Citations