Dynamischer Scheimpflug-Analyzer (Corvis ST) zur Bestimmung kornealer biomechanischer Parameter

Abstract: The Corvis ST allows a reliable characterization of the tissue structure and consistency of the cornea.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 46 publications
0
10
0
3
Order By: Relevance
“…More recently, Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) was introduced which measures the corneal deformation process in response to an air impulse and allows in vivo imaging of corneal biomechanical responses. [1317] It has been suggested to measure the changes in the elastic properties of the cornea, such as how stiff or soft the cornea is, and has been reported to be more useful in detecting the true biomechanical property of the cornea than ORA. [18]…”
Section: Introductionmentioning
confidence: 99%
“…More recently, Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) was introduced which measures the corneal deformation process in response to an air impulse and allows in vivo imaging of corneal biomechanical responses. [1317] It has been suggested to measure the changes in the elastic properties of the cornea, such as how stiff or soft the cornea is, and has been reported to be more useful in detecting the true biomechanical property of the cornea than ORA. [18]…”
Section: Introductionmentioning
confidence: 99%
“…B. die optische Kohärenzelastografie (OCE) [13], Brillouin-Spektroskopie [14] oder die Phase-Decorrelation-OCT (OCT: optische Kohärenztomografie) [15] liefern im Gegensatz zu den Non-Kontakt-Tonometriemethoden wie dem Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Deutschland) oder dem ORA (Reichert, Depew, NY, USA) ortsaufgelöste Information und bilden so die Realität besser ab. Der Vorteil der Non-Kontakt-Tonometrieverfahren liegt in einer einfachen Messung und der schnellen Akquisitionszeit [16]. In dieser Arbeit soll der gegenwärtige Stand der Erforschung der Brillouin-Spektroskopie für die ophthalmologische Klinik dargestellt und bewertet werden.…”
Section: Resultsunclassified
“…In contrast to noncontact tonometry methods such as the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) or the ORA (Reichert, Depew, NY, USA), the clinically acceptable corneal elasticity examination methods proposed in recent years, such as optical coherence elastography (OCE) [13], Brillouin spectroscopy [14], or phase decorrelation optical coherence tomography [15], provide space-resolved information and thus better reflect reality. The advantage of noncontact tonometry methods lies in the ease of measurement and the rapid acquisition time [16]. This paper aims to present and evaluate the current state of research on Brillouin spectroscopy in ophthalmology.…”
Section: Brillouin Spectroscopy In Ophthalmologymentioning
confidence: 99%
“…In addition, corneal tomographic maps can only detect corneal morphological changes, which have certain limitations for the diagnosis of subclinical or forme fruste keratoconus (Herber et al, 2018). In recent years, the development of corneal biomechanical measurement techniques such as Corvis ST and ORA grow rapidly, which can help us to understand the dynamic characteristics of cornea (Herber et al, 2019).…”
Section: Medical Examinationmentioning