2018
DOI: 10.1155/2018/7297635
|View full text |Cite
|
Sign up to set email alerts
|

Early Experience with Reduction of Unstable Pelvic Fracture Using a Computer-Aided Reduction Frame

Abstract: Purpose The optimal closed reduction technique for unstable pelvic fractures remains controversial. The purpose of this study is to verify the effectiveness and report early experiences with the reduction of unstable pelvic fractures using a computer-aided pelvic reduction frame. Methods From January 2015 to August 2016, a total of 10 patients with unilateral unstable pelvic fractures were included in this study. The surgical reduction procedure was based on the protocol of the computer-aided pelvic reduction … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 29 publications
(35 reference statements)
0
12
0
Order By: Relevance
“…A tremendous amount of caudad traction via transcondylar traction is required to reduce the cranially displaced posterior ring, but there are no good methods to resist this transcondylar traction 3, 5–8 . Several tools were developed to resist the transcondylar traction, including Matta frame 9 , Starr frame 10–12 , percutaneous Schantz screw in the greater trochanter 2 , and femoral distractor 4, 13 . However, when used with these tools, current closed reduction techniques have difficulties in achieving complete or nearly anatomical reduction of irreducible UVDPRD because hematoma maturation and soft tissue fibrosis often develop, which likely increase the risk of failed closed reduction of irreducible UVDPRD 4, 5, 8, 14 .…”
Section: Introductionmentioning
confidence: 99%
“…A tremendous amount of caudad traction via transcondylar traction is required to reduce the cranially displaced posterior ring, but there are no good methods to resist this transcondylar traction 3, 5–8 . Several tools were developed to resist the transcondylar traction, including Matta frame 9 , Starr frame 10–12 , percutaneous Schantz screw in the greater trochanter 2 , and femoral distractor 4, 13 . However, when used with these tools, current closed reduction techniques have difficulties in achieving complete or nearly anatomical reduction of irreducible UVDPRD because hematoma maturation and soft tissue fibrosis often develop, which likely increase the risk of failed closed reduction of irreducible UVDPRD 4, 5, 8, 14 .…”
Section: Introductionmentioning
confidence: 99%
“…With the promotion and popularization of early emergency treatment and reconstruction techniques for pelvic fractures, the success rate concerning early management of pelvic fractures has prominently improved, and most displaced unstable pelvic fractures can be reduced and xed early [10]. However, some severe pelvic fractures do not qualify for early reconstruction due to the need for early rescue for life-threatening massive bleeding and associated injuries [3,11].…”
Section: Discussionmentioning
confidence: 99%
“…For stable pelvic fractures, most doctors mainly adopt conservative treatment, including reduction through suspension traction, femoral supracondylar traction and lateral lying [3]. For unstable pelvic fractures, commonly methods of pelvic fracture reduction include external fixator therapy [4][5][6][7], open reduction and internal fixation [8], and percutaneous minimally invasive screw internal fixation [9]. With the development of medical robot technology, pelvic fracture reduction robot began to be applied in pelvic fracture reduction surgery [10][11][12].…”
Section: Introductionmentioning
confidence: 99%