2009
DOI: 10.1016/j.bios.2008.09.036
|View full text |Cite
|
Sign up to set email alerts
|

Easily made single-walled carbon nanotube surface microelectrodes for neuronal applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
49
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(50 citation statements)
references
References 41 publications
1
49
0
Order By: Relevance
“…Ben Jacob et al (2008) used planar CNTs-MEAs to record from and stimulate neuronal cell lines. APs generated by ganglion cells were recorded by SWCNT-MEAs in greater proportion when compared to geometrically identical Pt-MEAs (Gabriel et al, 2009). CNT probes developed to interface with neurons both intracellularly and extracellularly were comparable in performance to traditionally used glass electrodes with silver/silver chloride wires .…”
Section: Stimulation and Recording In Vitro Via Cnt Substratesmentioning
confidence: 92%
“…Ben Jacob et al (2008) used planar CNTs-MEAs to record from and stimulate neuronal cell lines. APs generated by ganglion cells were recorded by SWCNT-MEAs in greater proportion when compared to geometrically identical Pt-MEAs (Gabriel et al, 2009). CNT probes developed to interface with neurons both intracellularly and extracellularly were comparable in performance to traditionally used glass electrodes with silver/silver chloride wires .…”
Section: Stimulation and Recording In Vitro Via Cnt Substratesmentioning
confidence: 92%
“…The impedance per unit area was lower and the capacitance per unit area was higher for the OT-CNT probe compared to those of the CNT microelectrodes (Wang et al, 2006) and SWCNT surface microelectrodes (Gabriel et al, 2009). It could be attributed to that more CNT surface area was accessible in aqueous solution since the 3D CNT probe exhibited the more spreading CNTs.…”
Section: Cone-shaped 3d Cnt Probe Versus Other Cnt Electrodesmentioning
confidence: 94%
“…Instead, it relates to the characteristics of CNT electrode and the amplifier of instrument. The root-mean-square of the noise voltage was about 1.9 for the OT-CNT probe, which was lower than that of SWCNT surface microelectrodes (Gabriel et al, 2009). A lower value of rootmean-square of noise voltage for the OT-CNT probe well explained the lower noises to be added on the signals recorded by OT-CNT probes.…”
Section: Tablementioning
confidence: 96%
See 1 more Smart Citation
“…Ptblack plating (Rajaraman et al, 2011) J. Held O. Paul et al 64 S,R Pt/TiW on < 10 µm high, µm Ø Ag or sub-µm Ø Si (electroporation) microneedles on Si insulated by Si 3 N 4 (Held et al, 2008;Held, Gaspar, et al, 2010 (Gabriel et al, 2009;Bongard et al, 2010) A. Hai J. Shappir M. Spira et al…”
Section: R+49smentioning
confidence: 99%