Economic analysis of data center cooling strategies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…Additionally, supercomputer architecture, parallel science, and parallel software development can provide opportunities for energy conservation [11][12][13][14]. For energy conservation of ACS, there are four main considerations: (1) appropriate cooling strategy [15]; (2) good layout design and air flow distribution for computer rooms [16,17]; (3) economizer cycles [18,19]; and (4) simulation-based control [20]. In addition to these, the use of heat pipes [5,[21][22][23] and free-cooling [24][25][26] in data centers was also attempted.…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, supercomputer architecture, parallel science, and parallel software development can provide opportunities for energy conservation [11][12][13][14]. For energy conservation of ACS, there are four main considerations: (1) appropriate cooling strategy [15]; (2) good layout design and air flow distribution for computer rooms [16,17]; (3) economizer cycles [18,19]; and (4) simulation-based control [20]. In addition to these, the use of heat pipes [5,[21][22][23] and free-cooling [24][25][26] in data centers was also attempted.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Equation (14) indicates that the output power of cooling storage at time t must be less than the maximum power of cooling storage. Equation (15) means that the cooling storage for one day cannot be used for the next day. In summary, Equation (2) is dependent on Equations (7)-(15).…”
Section: Configuration Modelmentioning
confidence: 99%
“…They identified the economic advantage of using WSE applications because of increased energy costs for ASEs due to humidification and dehumidification requirements and higher initial cost. Cho et al [18] compared ASEs, WSEs, and combinations of them for a DC that operates at relatively low temperatures (5 • C chilled water temperature ( T chw )). They concluded that an ASE with additional mechanical cooling is the most economical option.…”
Section: Racks R R R R Ra a A A A A A A A A A A A A A A A A A A A A Amentioning
confidence: 99%
“…Table 4 lists the economic lives of various equipment, which appear to be typically greater than 15 years. 18 Spangler and Jeffers assumed 15 years of economic life for the TCO analysis assessing the economic benefit of two economizer applications in DCs [17]. Hence, 15 years of life for economic assessment is a reasonable assumption for this study.…”
Section: Discount and Inflation Ratesmentioning
confidence: 99%
“…2019, 9, 3850 2 of 30 the world host on their servers organizations with databases, every Internet website, and cloud services. Data centers are consuming more and more electricity worldwide [4][5][6]. In 2012, the entire consumption of data centers was assessed to be near 270 TWh [7].…”