2020
DOI: 10.3390/en13112928
|View full text |Cite
|
Sign up to set email alerts
|

Economic Analysis of Integrated Ground Source Heat Pumps on a Shared Ground Loop

Abstract: An integrated geothermal system in which heat pumps for air conditioning and hot water both share the same ground loop was proposed in our previous study. Although this system produced electricity savings of 15% compared to a conventional system in which the two heat pumps operated on their own ground loop, practical requirements regarding further lowering the operation cost of the integrated geothermal system and the possibility of the energy savings being low during winter initiated further investigation int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…The investment costs reduce on the basis that a single larger ground loop will not cost as much as two separate GSHPs 3. Optimization of the heat pump (i.e., operational sequencing) will leads to more energy savings [45] and minimize the boreholes depletion.…”
Section: Geothermalmentioning
confidence: 99%
“…The investment costs reduce on the basis that a single larger ground loop will not cost as much as two separate GSHPs 3. Optimization of the heat pump (i.e., operational sequencing) will leads to more energy savings [45] and minimize the boreholes depletion.…”
Section: Geothermalmentioning
confidence: 99%
“…With the development of heat pump technology, water loop heat pump systems began to be modified. Heat pumps were connected to the loop using various lower heat sources, such as ground [6,7,8], air and surface and deep water [9]. Such systems allow limiting the functions to heating or cooling only, as presented in Fig.…”
Section: Offices and Services 100mentioning
confidence: 99%
“…The authors realize that insufficient energy (and financial) savings occur in the winter season; therefore, they investigate in another work Shin et al [148] the electricity savings and economic benefits of including an outdoor air reset control (OARC) to regulate the production of domestic hot water according to the outdoor temperature. Further, they include a thermal storage tank for the domestic hot water and test the system functioning in sequential mode, alternating the functioning of the HP for air conditioning and the HP for hot water.…”
Section: Advanced and Integrated Solutionsmentioning