Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background Aortic Stenosis (AS) is the most commonly acquired valvular pathology in the western world. AS severity is typically evaluated with Doppler echocardiography. Evaluation of aortic gradients using standard Doppler echocardiography from the apical window may underestimate the true gradient due to misalignment of blood flow to the ultrasound beam and is often better evaluated from other imaging windows using a Non-imaging Continuous-Wave Doppler (NI-CWD) probe. Herein, we describe a unique case of aortic stenosis being underestimated by dynamic acoustic shadowing from the apical window rather than beam misalignment. Case Summary The patient is a Hispanic 31-year-old male with a congenital bicuspid aortic valve who underwent a balloon aortic valvuloplasty at age 13. At age 31 the patient underwent a repeat transthoracic echocardiogram (TTE) that was largely unchanged from his prior TTE from 15 years prior. Notably on this TTE, there was acoustic shadowing of color Doppler in the distal left ventricular outflow tract and aortic valve during systole. While gradients only suggested moderate aortic stenosis, the degree of left ventricular hypertrophy was suspicious for more severe aortic stenosis. Only by using the NI-CWD probe at the right sternal border were we able to identify very-severe aortic stenosis with a peak velocity of 6.5 m/s and a mean gradient of 100 mmHg. Discussion In our specific case, dynamic acoustic shadowing of the aortic valve from the apical window obscured both imaging and Doppler signals. This acoustic shadowing was not present from the right sternal border with the NI-CWD probe, leading to an over 100% increase in aortic valve peak velocity and proper correction of AS severity. This allowed for expedited care and underscores the importance of such techniques.
Background Aortic Stenosis (AS) is the most commonly acquired valvular pathology in the western world. AS severity is typically evaluated with Doppler echocardiography. Evaluation of aortic gradients using standard Doppler echocardiography from the apical window may underestimate the true gradient due to misalignment of blood flow to the ultrasound beam and is often better evaluated from other imaging windows using a Non-imaging Continuous-Wave Doppler (NI-CWD) probe. Herein, we describe a unique case of aortic stenosis being underestimated by dynamic acoustic shadowing from the apical window rather than beam misalignment. Case Summary The patient is a Hispanic 31-year-old male with a congenital bicuspid aortic valve who underwent a balloon aortic valvuloplasty at age 13. At age 31 the patient underwent a repeat transthoracic echocardiogram (TTE) that was largely unchanged from his prior TTE from 15 years prior. Notably on this TTE, there was acoustic shadowing of color Doppler in the distal left ventricular outflow tract and aortic valve during systole. While gradients only suggested moderate aortic stenosis, the degree of left ventricular hypertrophy was suspicious for more severe aortic stenosis. Only by using the NI-CWD probe at the right sternal border were we able to identify very-severe aortic stenosis with a peak velocity of 6.5 m/s and a mean gradient of 100 mmHg. Discussion In our specific case, dynamic acoustic shadowing of the aortic valve from the apical window obscured both imaging and Doppler signals. This acoustic shadowing was not present from the right sternal border with the NI-CWD probe, leading to an over 100% increase in aortic valve peak velocity and proper correction of AS severity. This allowed for expedited care and underscores the importance of such techniques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.