Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers

Abstract: Patients with a permanent pacemaker are currently restricted from diagnostic nuclear magnetic resonance (NMR) imaging because of potential adverse effects on the pacemaker by the magnet. Previous work has shown that NMR imaging will result in asynchronous pacing of the pulse generator within a given distance of the magnet. The radiofrequency signal generated by the system may also result in rapid cardiac pacing, which may have deleterious effects. This study utilized a 1.5 tesla unit in an in vivo laboratory a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
73
0
1

Year Published

1999
1999
2008
2008

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 129 publications
(74 citation statements)
references
References 4 publications
0
73
0
1
Order By: Relevance
“…18 Strong electromagnetic fields may also cause asynchronous pacing, activate tachyarrhythmia therapies, or inhibit a demand pacemaker. 19 Despite these concerns, previous case series have reported the safety of MRI in the setting of pacemakers.…”
Section: Editorial P 1232 Clinical Perspective P 1284mentioning
confidence: 99%
“…18 Strong electromagnetic fields may also cause asynchronous pacing, activate tachyarrhythmia therapies, or inhibit a demand pacemaker. 19 Despite these concerns, previous case series have reported the safety of MRI in the setting of pacemakers.…”
Section: Editorial P 1232 Clinical Perspective P 1284mentioning
confidence: 99%
“…Cardiac pacemakers present potential problems to patients undergoing MR procedures from several mechanisms, including: 1) movement of the pacemaker (implantable pulse generator and/or leads) due to the strong static magnetic field of the MR system; 2) MRIrelated heating of the pacemaker lead by the time-varying fields; 3) inhibition or modification of the function of the pacemaker by the electromagnetic fields used for MRI; and 4) inappropriate or rapid pacing due to pulsed gradient magnetic fields and/or pulsed radio frequency (RF) fields (i.e., electromagnetic interference) from the operating MR system (i.e., with the pacing lead acting as an antenna) (4,5,8,(45)(46)(47)(48)(49)(50)(51)(52)(53)(54)(55)(56)(57)(58)(59)(60). These problems may result in serious injuries or lethal consequences for patients.…”
Section: Mr Safe Fiber-optic Cardiac Pacing Leadmentioning
confidence: 99%
“…The potential effects of MRI on PMs, ICDs, and other active implantable medical devices (AIMDs) include: force and torque effects (7,8); an undefined reedswitch state within the static magnetic field (9); the potential risk of heart stimulation and inappropriate pacing (10,11); and heating effects at the lead tip (12)(13)(14).…”
mentioning
confidence: 99%