2019
DOI: 10.1016/j.spmi.2019.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Effect of BlueP/MoS2 Heterostructure and Graphene layer on the Performance Parameter of SPR Sensor: Theoretical insight

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2
1

Relationship

3
4

Authors

Journals

citations
Cited by 52 publications
(19 citation statements)
references
References 26 publications
0
19
0
Order By: Relevance
“…However, when sensing structure works in the visible region [32–34] (633 nm incident light wavelength) the relative sensitivity obtained as 68.52°/RIU, which is greater than the previous case. Sensitivity enhancement is directly related to the metal nature having a complex refractive index.…”
Section: Resultsmentioning
confidence: 83%
See 1 more Smart Citation
“…However, when sensing structure works in the visible region [32–34] (633 nm incident light wavelength) the relative sensitivity obtained as 68.52°/RIU, which is greater than the previous case. Sensitivity enhancement is directly related to the metal nature having a complex refractive index.…”
Section: Resultsmentioning
confidence: 83%
“…Reflection and transmission of the proposed multi-layered structure or the reflectivity of P polarized light can be calculated by transfer matrix method [31][32][33]. The tangential field between the boundaries is related by-…”
Section: Excitation Of Surface Plasmons As Well As Their Typesmentioning
confidence: 99%
“…For example, Prajapati and Srivastava proposed a optical biosensing based on SPR technology—blue P/MoS 2 heterostructure and graphene combination. [ 130 ] As shown in Figure 14 a , p‐polarized light is incident on BK7 metal‐coated prism at a certain angle, and the incident angle is changed according to the angle inquiry method. However, the gold layer has poor absorption of biomolecules, which limits the sensitivity of conventional biosensors.…”
Section: Optical Biosensors Based On 2d Materialsmentioning
confidence: 99%
“…By applying a thin silicon layer directly over the bimetallic layer, it is observed that the sensitivity enhanced significantly. Existence of dielectric silicon layer enhances the field intensity of the exciting light [26]. In a conventional SPR sensor, the only metal layer is responsible for absorption whereas due to the addition of silicon layer the absorption takes place both in metal as well as silicon layer.…”
Section: Theoretical Mathematical Overview and Design Considerationmentioning
confidence: 99%