2017
DOI: 10.1177/1687814017730534
|View full text |Cite
|
Sign up to set email alerts
|

Effect of cutting fluids on corrosion properties and turning surface quality of Fe-based superalloy

Abstract: As the steam turbine rotor works in extreme conditions of high temperature, pressure, speed, and load, better material performance and machined surface quality are highly demanded. Fe-based superalloy is a kind of typical difficultto-cut material that is widely used as steam turbine rotors, and cutting fluid is necessary during its machining process. However, many accidents occurred for the misuse of cutting fluids. The effect of cutting fluids on material characteristics and physical mechanical properties can… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…There are only a few articles on corrosion caused by cutting fluid. Zhu J. et al [7] studied corrosion behavior of Fe-based superalloy in cutting fluid. The results show significant corrosion of Fe-based superalloy after prolonged Molecules 2023, 28, 3648 2 of 17 exposure to cutting fluid.…”
Section: Introductionmentioning
confidence: 99%
“…There are only a few articles on corrosion caused by cutting fluid. Zhu J. et al [7] studied corrosion behavior of Fe-based superalloy in cutting fluid. The results show significant corrosion of Fe-based superalloy after prolonged Molecules 2023, 28, 3648 2 of 17 exposure to cutting fluid.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the bio-based nanolubricants were properly formulated to achieve a pH of 9.2 as cutting fluids with pH lower than 7 have the tendency to corrode Fe alloys, while those with pH above 10 may be harmful to humans. It is worth to highlight that the suitable pH value according to International Standard Organisation (ISO) is between 8.0 and 9.5 [25]. Meanwhile, the biodegradable test was conducted for 28 days using the OECD-301D closed bottle test.…”
Section: Lubrication Propertiesmentioning
confidence: 99%
“…Interaction plot for BA, device state x chloride concentration Some works and reports are available on corrosiveness of cutting, machining and drawing fluids[18][19][20][21] .…”
mentioning
confidence: 99%