2017
DOI: 10.4103/ijn.ijn_64_17
|View full text |Cite
|
Sign up to set email alerts
|

Effect of double filtration plasmapheresis on various plasma components and patient safety: A prospective observational cohort study

Abstract: Double filtration plasmapheresis (DFPP) was historically used for blood group incompatible renal transplantation. Very few studies are available worldwide regarding its efficiency in removing specific plasma components, and safety. We conducted a prospective observational cohort study over 1 year on patients undergoing DFPP for various renal indications. There were 15 patients with 39 sessions. The pre- and post-procedure plasma samples of serum IgG, IgA, IgM, fibrinogen, calcium, phosphate, potassium, and mag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 15 publications
(26 reference statements)
0
9
0
Order By: Relevance
“…Human albumin can be used as the alternative replacement fluid, but it is much more expensive relative to plasma. [ 13 ] Thus, we are interested to explore the therapeutic potential of DFPP on HTG-AP and further scrutinize the patients’ outcome.…”
Section: Introductionmentioning
confidence: 99%
“…Human albumin can be used as the alternative replacement fluid, but it is much more expensive relative to plasma. [ 13 ] Thus, we are interested to explore the therapeutic potential of DFPP on HTG-AP and further scrutinize the patients’ outcome.…”
Section: Introductionmentioning
confidence: 99%
“…This activates the coagulation cascade and also leads to platelet activation. As a result, anticoagulation is often used to maintain blood flow and allow effective treatment [6].…”
Section: Discussionmentioning
confidence: 99%
“…In this regard, there is a report of double filtration plasmapheresis (DFPP) to reduce viral RNA for the hepatitis C virus (HCV) with the reason that HCV particles are large enough (approximate diameter 55-60 nm) to not pass through the membrane so they can be eliminated [ 2 ]. Considering the size of the SARS-CoV2(60-140 nm), the use of DFFP seems to be effective in reducing the virus load due to its ability to remove particles larger than 60 nm [ [31] , [32] , [33] ].…”
Section: Therapeutic Potential Of Plasma Exhange In Covid-19mentioning
confidence: 99%