2012
DOI: 10.4012/dmj.2010-201
|View full text |Cite
|
Sign up to set email alerts
|

Effect of immersion disinfection of alginate impressions in sodium hypochlorite solution on the dimensional changes of stone models

Abstract: This study investigated the effect of the immersion of alginate impressions in 0.5% sodium hypochlorite solution for 15 min on the dimensional changes of stone models designed to simulate a sectional form of a residual ridge. Five brands of alginate impression materials, which underwent various dimensional changes in water, were used. A stone model made with an impression that had not been immersed was prepared as a control. The immersion of two brands of alginate impressions that underwent small dimensional c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
0
9

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(36 citation statements)
references
References 12 publications
0
27
0
9
Order By: Relevance
“…Disinfectants must be effective as antimicrobial agents while not adversely affecting the dimensional accuracy or feature fidelity of the impression material and the resulting gypsum cast (7). The American Dental Association (ADA) recommends that alginate impressions be sprayed with an ADA-approved disinfectant and then sealed in a plastic bag for the recommended disinfection time (1,2). Spray disinfection of alginate impressions with 1% sodium hypochlorite (NaOCl) or 2% glutaraldehyde reportedly did not cause adverse dimensional changes or surface deterioration of stone models produced from the impressions (2,8).…”
Section: Surface Detail Reproduction and Dimensional Accuracy Of Stonmentioning
confidence: 99%
See 1 more Smart Citation
“…Disinfectants must be effective as antimicrobial agents while not adversely affecting the dimensional accuracy or feature fidelity of the impression material and the resulting gypsum cast (7). The American Dental Association (ADA) recommends that alginate impressions be sprayed with an ADA-approved disinfectant and then sealed in a plastic bag for the recommended disinfection time (1,2). Spray disinfection of alginate impressions with 1% sodium hypochlorite (NaOCl) or 2% glutaraldehyde reportedly did not cause adverse dimensional changes or surface deterioration of stone models produced from the impressions (2,8).…”
Section: Surface Detail Reproduction and Dimensional Accuracy Of Stonmentioning
confidence: 99%
“…Disinfection of tools and materials is an important step in dental procedures (1)(2)(3). In the absence of disinfection, treatment procedures can expose dentists, hygienists and laboratory workers to direct or crosscontamination (4,5).…”
Section: Introductionmentioning
confidence: 99%
“…Boyutsal değişimin 15 µm'den az olduğu ve genel kanının aksine bu çalışmada daldırma yönteminin aljinat ölçü maddelerinin dezenfeksiyonunda kullanılabilir bir yöntem olduğu öne sürülmüştür. 37 Dezenfeksiyon yönteminin, aljinat ölçü maddelerinin sağladığı yüzey detayı üzerindeki etkisinin incelendiği bir araştırmada, ölçüler sodyum hipoklorit solüsyonunda 1, 5 ve 10 dakika bekletilerek veya 6, 12 ve 18 dakika boyunca ultraviyole uygulanarak dezenfekte edilmiştir. Kontrol grubu ile karşılaştırıldığında, test edilen gruplarda yüzey detayı açısından istatistiksel olarak anlamlı bir fark gösterilmemiştir.…”
Section: Introductionunclassified
“…Quality of diagnostic stone models has a critical role in the orthodontic treatment plan and evaluation of the treatment results. 4,5 The aim of this study was to evaluate the dimensional stability of five irreversible hydrocolloid impression materials according to the different storage condition and periods. The null hypothesis of this study was that the storage conditions and periods would not affect the dimensional stability of irreversible hydrocolloid impression materials.…”
Section: Introductionmentioning
confidence: 99%
“…1 Some factors such as type of impression material 4 and impression tray, storage condition and storage period can affect the dimensional stability of irreversible impression materials and hence the accuracy of diagnostic stone models. Quality of diagnostic stone models has a critical role in the orthodontic treatment plan and evaluation of the treatment results.…”
Section: Introductionmentioning
confidence: 99%