2009
DOI: 10.1563/1548-1336-35.3.130
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Implant Design on Initial Stability of Tapered Implants

Abstract: Implant design is one of the parameters for achieving successful primary stability. This study aims to examine the effect of a self-tapping blades implant design on initial stability in tapered implants. Polyurethane blocks of different densities were used to simulate different bone densities. The two different implant designs included one with self-tapping blades and one without self-tapping blades. Implants were placed at 3 different depths: apical third, middle third, and fully inserted at 3 different densi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
92
1
23

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 89 publications
(119 citation statements)
references
References 9 publications
3
92
1
23
Order By: Relevance
“…Moreover, it is important to note that, depending on a material's density, it may show some similarity regarding the effects of the resonance frequency analysis when this density is similar to that of another substrate. The studies of Chong et al 9 show that resonance frequency readings prove to be similar when implants are inserted in higher density polyurethane (50 PCF, equivalent to D1 type bone) and average density polyurethane (40 PCF, similar to D2 type bone). This study also shows statistically similar results for polyurethane specimens with approximate densities of 20 and 15 PCF and Synbone, both in machined implants and surface treated implants.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Moreover, it is important to note that, depending on a material's density, it may show some similarity regarding the effects of the resonance frequency analysis when this density is similar to that of another substrate. The studies of Chong et al 9 show that resonance frequency readings prove to be similar when implants are inserted in higher density polyurethane (50 PCF, equivalent to D1 type bone) and average density polyurethane (40 PCF, similar to D2 type bone). This study also shows statistically similar results for polyurethane specimens with approximate densities of 20 and 15 PCF and Synbone, both in machined implants and surface treated implants.…”
Section: Discussionmentioning
confidence: 99%
“…Degidi et al 7 claim that a surgeon's ability to predict primary stability through subjective analysis is not always effective, mainly with low resonance frequency and insertion torque values. Therefore, more objective, systematic measurements must be encouraged, mainly in cases where an immediate loading regimen is the aim, where knowing the implant's initial stability, immediately after insertion in the bone, is of crucial importance in defining the opportune moment for the application of load 5,7,13 so as to ensure natural healing and effective bone formation, thereby enabling optimal stress distribution of functional masticatory loading 9 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations