Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a light scattering polymer dispersed liquid crystal (PDLC) filter with scatterers of submicron size in front of the normal eye. All measurements were made using each of three broad-band color stimuli - red, green and blue (produced either with LEDs or a color CRT monitor). Differences were found in both the level and the spectral characteristics of scattering under the different conditions. The measured values of the straylight parameter, s, in artificial fog showed no noticeable spectral dependence at any visibility range. Increasing the visibility range caused an exponential decrease in the straylight. Intraocular straylight measured with the clear eye showed an increase at the red and blue ends of the spectrum as compared to the green. Straylight measured using PDLC plates with different transparency levels showed a spectral dependence which decreased with wavelength. The scattering introduced by the PDLC plate therefore failed to give a valid simulation of cataract and fog conditions for polychromatic stimuli, due to its erroneous spectral dependence.
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a light scattering polymer dispersed liquid crystal (PDLC) filter with scatterers of submicron size in front of the normal eye. All measurements were made using each of three broad-band color stimuli - red, green and blue (produced either with LEDs or a color CRT monitor). Differences were found in both the level and the spectral characteristics of scattering under the different conditions. The measured values of the straylight parameter, s, in artificial fog showed no noticeable spectral dependence at any visibility range. Increasing the visibility range caused an exponential decrease in the straylight. Intraocular straylight measured with the clear eye showed an increase at the red and blue ends of the spectrum as compared to the green. Straylight measured using PDLC plates with different transparency levels showed a spectral dependence which decreased with wavelength. The scattering introduced by the PDLC plate therefore failed to give a valid simulation of cataract and fog conditions for polychromatic stimuli, due to its erroneous spectral dependence.
Tato metodika byla vytvořena se státní podporou Technologické agentury ČR v rámci Programu TAČR ÉTA 2, projekt č. TL02000183 "Člověk a bezpečnost v dopravě v souvislosti s rozvojem světelných technologií".Neoprávněné užití tohoto díla je porušením autorských práv a může zakládat občanskoprávní, správněprávní, popř. trestněprávní odpovědnost.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.