2005
DOI: 10.1016/j.ces.2004.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Effect of liquid properties on the performance of bubble column reactors with fine pore spargers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

15
111
0
3

Year Published

2008
2008
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 169 publications
(129 citation statements)
references
References 17 publications
15
111
0
3
Order By: Relevance
“…Finally, at the heterogeneous regime the gas holdup continues to increase, but with a lower slope than the homogeneous regime [6]. Figure 6 shows the dependence of gas holdup on corresponding gas superficial velocity for the two bubble columns used.…”
Section: Gas Holdupmentioning
confidence: 96%
See 1 more Smart Citation
“…Finally, at the heterogeneous regime the gas holdup continues to increase, but with a lower slope than the homogeneous regime [6]. Figure 6 shows the dependence of gas holdup on corresponding gas superficial velocity for the two bubble columns used.…”
Section: Gas Holdupmentioning
confidence: 96%
“…In previous works conducted in this laboratory [2,[6][7][8] we have experimentally studied the effect of the sparger characteristics (i.e. diameter, pore size), the liquid physical properties and the gas flow rate on the performance of a bubble column equipped with a fine pore sparger.…”
Section: Introductionmentioning
confidence: 99%
“…Also, the presence of ethanol in the liquid mixture reduced the surface tension of the liquid which enhanced the reduction of bubble size formed [19,20].…”
Section: Bubble Size Analysismentioning
confidence: 99%
“…More recent work has used photography [23]- [25][44]- [47], nonisokinetic withdrawal in conjunction with electro-optic detection [48], two needle local probes [49], four fibre optic probes [50] and a Wire Mesh Sensor [21]. The liquids used were almost exclusively water with different chemical dissolved in them, e.g., Na2CO3, NaHCO3, NaOH [43], DEA [44], TEA [45], polymer plus surfactant [46] and surfactant [47].…”
Section: Figmentioning
confidence: 99%
“…However, the data on the effect of liquid viscosity are limited. The liquid viscosity investigated in [23] is up to 0.02 Pa s. The Wire Mesh Sensor was also employed to study the bubble behaviour of silicone oil (properties given in Table 1) [51] The objective of this study is to show that a liquid, an aqueous solution of glycerol/potassium chloride whose physical properties are similar to the ionic liquid, e.g.,…”
Section: Figmentioning
confidence: 99%