2019
DOI: 10.3938/jkps.74.724
|View full text |Cite|
|
Sign up to set email alerts
|

Effect of Minimum Segment Width on Gamma Passing Rate Considering MLC Position Error for Volumetric Modulated Arc Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 17 publications
0
8
0
1
Order By: Relevance
“…Previous studies have identified the effects of MSW on the quality of VMAT plans for multiple VMAT cases in clinical treatment. 8 , 26 , 27 , 28 Wang et al. and Nithyanantham et al.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Previous studies have identified the effects of MSW on the quality of VMAT plans for multiple VMAT cases in clinical treatment. 8 , 26 , 27 , 28 Wang et al. and Nithyanantham et al.…”
Section: Discussionmentioning
confidence: 99%
“…Previous studies have identified the effects of MSW on the quality of VMAT plans for multiple VMAT cases in clinical treatment. 8,[26][27][28] Wang et al and Nithyanantham et al reported the influence of MSW on the quality and delivery accuracy of VMAT plans for cervix cancer and stereotactic body radiotherapy. 8,26 The studies demonstrated a similar result to the present study with regards to reduced MU and treatment time with increased MSW.…”
Section: Plan Deliverability (Difference-tps Vs Measured)mentioning
confidence: 99%
See 1 more Smart Citation
“…Small MSWs improve the quality by raising the TV coverage and protecting OARs; 7 , 28 , 29 they also prolong the treatment DT and reduce the treatment plan’s efficiency. 5 , 7 , 30 , 31 Plans with smaller MSWs require higher treatment accuracy and are more easily affected by errors in the setup and multileaf collimator position. 5 Therefore, an appropriate MSW value is essential for radiotherapy plans.…”
Section: Discussionmentioning
confidence: 99%
“…The choice of different segment settings might affect the optimization of the target area as well as the modulation and, accordingly, the plan delivery and verification passing rate. 5 , 6 Until now, few studies have reported the influence of MSW optimization on IMRT plan quality, delivery, and efficiency, 7 and no related research on esophageal cancer has been found. In this study, 20 patients suffering from local-regional stage esophageal cancer were enrolled to explore the impact of MSW values on IMRT plan quality and delivery efficiency to provide a clinical reference for the IMRT plan design for esophageal cancer.…”
Section: Introductionmentioning
confidence: 99%