2010
DOI: 10.1016/j.jsbmb.2010.03.014
|View full text |Cite
|
Sign up to set email alerts
|

Effect of mutations of the human serpin protein corticosteroid-binding globulin on cortisol-binding, thermal and protease sensitivity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
6
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 41 publications
1
6
0
Order By: Relevance
“…This is consistent with other findings [17]. On the other hand, as expected, cleaved CBG was not recognised by the RCL monoclonal antibody as the epitope exactly spanned the elastase cleavage site.…”
Section: Discussionsupporting
confidence: 93%
See 2 more Smart Citations
“…This is consistent with other findings [17]. On the other hand, as expected, cleaved CBG was not recognised by the RCL monoclonal antibody as the epitope exactly spanned the elastase cleavage site.…”
Section: Discussionsupporting
confidence: 93%
“…Elastase cleaved CBG with substitutions at the P16 residue (Glu 334 Gly or Glu 334 Ala) that show complete loss of cortisol binding [7] may not be expected to be recognised by these RCL monoclonal antibodies and other human CBG mutants with differences in ligand binding sensitivity to heat or elastase [17] are also likely candidates for the use of these novel RCL antibodies. Similarly the investigation of the temperature dependent release of cortisol from CBG could prove useful as the reactive centre loop region is temperature responsive [19].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…SerpinA6 , also known as cortisol binding globulin or transcortin has been shown to alter cortisol binding and degradation when mutated. 17 This finding lends biologic plausibility to genetic variation in SerpinA6 being associated with altered cortisol effectiveness and risk of RDS and respiratory impairment.…”
Section: Discussionmentioning
confidence: 84%
“…Total plasma cortisol was low after stimulation with synthetic adrenocorticotropic hormone (ACTH); however, 24-h urinary free cortisol excretion was normal. Elevated plasma-free Table 4) [ 66,96]. Interestingly these studies have shown that mutations, particularly within the RCL at threonine 342 confer resistance to protease cleavage [96].…”
Section: Human Observationsmentioning
confidence: 99%