2021
DOI: 10.3390/app11167468
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Non-Homogeneous Soil Characteristics on Substation Grounding-Grid Performances: A Review

Abstract: Designing an effective grounding system for AC substations needs predetermination of ground resistance and ground potential distribution caused by fault current’s presence in the ground. Therefore, it is necessary to have a suitable grounding grid structure in the soil properties in which the grid is buried. Though the soil composition where the grounding grid is located is typically non-homogeneous, the soil is often presumed to be homogeneous due to the complexities of grounding system analysis in non-homoge… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
0
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 59 publications
0
0
0
3
Order By: Relevance
“…Analisis menggunakan metode Two-layer Soil Vertical Rod Configuration ini mengetahui sifat tanah dalam suatu rangkaian pentanahan baik itu resistif, induktif maupun kapasitif [10]. Pengujian dilakukan dengan mengubahubah besaran frekuensi yang bertujuan untuk mengukur respon sistem pentanahan terhadap gangguan berfrekuensi tinggi, seperti petir atau gangguan lainnya yang mungkin menyebabkan efek elektromagnetik berfrekuensi tinggi [11].…”
Section: Pendahuluanunclassified
“…Analisis menggunakan metode Two-layer Soil Vertical Rod Configuration ini mengetahui sifat tanah dalam suatu rangkaian pentanahan baik itu resistif, induktif maupun kapasitif [10]. Pengujian dilakukan dengan mengubahubah besaran frekuensi yang bertujuan untuk mengukur respon sistem pentanahan terhadap gangguan berfrekuensi tinggi, seperti petir atau gangguan lainnya yang mungkin menyebabkan efek elektromagnetik berfrekuensi tinggi [11].…”
Section: Pendahuluanunclassified
“…Para evitar la corrosión del CP y de la unión con la malla, deben considerarse sales minerales que se ionizan formando un electrolito sólido con el pH que varía entre 8 y 10. En subestaciones eléctricas en áreas urbanas, se contemplan las partes metálicas que pueden modificar la distribución de potencial eléctrico [36], [37], [38].…”
Section: Trabajos Relacionadosunclassified
“…La Tabla 2 resume los trabajos relacionados de las recomendaciones propuestas por varios autores con respecto al diseño de sistemas de puesta a tierra y el comportamiento de los gradientes de potencial que ocurren en las estructuras metálicas circundantes. ✠ ✠ ✠ Permal, 2021 [36] ✠ ✠ Elmashtoly, 2021 [34] ✠ ✠ ✠ Popovic, 2021 [6] ✠ ✠ ✠ Liu, 2021 [41] ✠ ✠ ✠ ✠ Kuchler, 2021 [43] ✠ ✠ ✠ Kavimandan, 2020 [23] ✠ ✠ Tian, 2020 [39] ✠ ✠ DiSilvestre, 2019 [4] ✠ ✠ ✠ ✠ Di Silvestre, 2018 [19] ✠ ✠ Shabangu, 2017 [13] ✠…”
Section: Trabajos Relacionadosunclassified