2023
DOI: 10.1016/j.soildyn.2023.107929
|View full text |Cite
|
Sign up to set email alerts
|

Effect of oblique incidence angle and frequency content of P and SV waves on the dynamic behavior of liquid tanks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Xu et al [28] developed a shaking-table test approach to analyze the dynamic behaviors of a tank that incorporates soil-structure interaction. Bi et al [29] proposed a model for investigating the hydrodynamic pressures of a storage tank under earthquakes with various incidence angles taking coupled acoustic-structural interaction into account. Jaramillo et al [30] presented an efficient model considering soilfoundation-structure interaction and obtained influences of soil flexibility on earthquake responses of sloshing involving soil-tank interaction.…”
Section: Introductionmentioning
confidence: 99%
“…Xu et al [28] developed a shaking-table test approach to analyze the dynamic behaviors of a tank that incorporates soil-structure interaction. Bi et al [29] proposed a model for investigating the hydrodynamic pressures of a storage tank under earthquakes with various incidence angles taking coupled acoustic-structural interaction into account. Jaramillo et al [30] presented an efficient model considering soilfoundation-structure interaction and obtained influences of soil flexibility on earthquake responses of sloshing involving soil-tank interaction.…”
Section: Introductionmentioning
confidence: 99%
“…They found that the impulsive and convective responses of the tank are greatly affected by changing the incident angle. The effects of incident angle on the convective and impulsive responses of a concrete liquid storage tank were studied by [47]. In the presence of seven different incident angles, both the convective and impulsive responses of the liquid storage tank were found to be sensitive to angle variations.…”
Section: Introductionmentioning
confidence: 99%
“…In the presence of seven different incident angles, both the convective and impulsive responses of the liquid storage tank were found to be sensitive to angle variations. It has been demonstrated by [47] that the angle of incidence of input ground motions greatly affects the seismic response of rectangular liquid storage tanks. According to that study of rectangular liquid storage tanks with three different planar aspect ratios, structural displacement is related to the sloshing response, such that the sloshing height increases when the structural displacement decreases with a change in the angle of incidence.…”
Section: Introductionmentioning
confidence: 99%