2021
DOI: 10.1016/j.foodcont.2020.107494
|View full text |Cite
|
Sign up to set email alerts
|

Effect of physicochemical factors and use of milk powder on milk rennet-coagulation: Process understanding by near infrared spectroscopy and chemometrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
11
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 37 publications
1
11
0
1
Order By: Relevance
“…The effect of physicochemical factors, as well as the utilization of skim milk powder on milk rennet-coagulation, was evaluated by using NIR spectroscopy and multivariate curve resolution alternating least squares (MCR-ALS) [24]. Coagulum formation has been evaluated by using reference methods as well as by the utilization of NIR spectroscopy analyzing unaltered reconstituted milk samples, pasteurized samples, samples with calcium chloride addition and samples of reconstituted milk mixed with fresh milk [24]. The calibration models were able to monitor changes during processing, explaining more than 99.9% of variance in the dataset [24].…”
Section: Dairy Productsmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect of physicochemical factors, as well as the utilization of skim milk powder on milk rennet-coagulation, was evaluated by using NIR spectroscopy and multivariate curve resolution alternating least squares (MCR-ALS) [24]. Coagulum formation has been evaluated by using reference methods as well as by the utilization of NIR spectroscopy analyzing unaltered reconstituted milk samples, pasteurized samples, samples with calcium chloride addition and samples of reconstituted milk mixed with fresh milk [24]. The calibration models were able to monitor changes during processing, explaining more than 99.9% of variance in the dataset [24].…”
Section: Dairy Productsmentioning
confidence: 99%
“…Coagulum formation has been evaluated by using reference methods as well as by the utilization of NIR spectroscopy analyzing unaltered reconstituted milk samples, pasteurized samples, samples with calcium chloride addition and samples of reconstituted milk mixed with fresh milk [24]. The calibration models were able to monitor changes during processing, explaining more than 99.9% of variance in the dataset [24]. The authors concluded that the NIR models were able to monitor a diverse range of coagulation conditions, demonstrating the suitability of this technique for evaluating the rennet-induced coagulation of reconstituted milk [24].…”
Section: Dairy Productsmentioning
confidence: 99%
“…Суть второго направления инфракрасных методов исследований состоит в том, что детектор, погруженный в неподвижный образец молока в процессе сычужной коагуляции, регистрирует поглощение на одной длине волны ближнего инфракрасного диапазона (NIR) [17]. Этот принцип реализован в приборе Optigraph (OPT, Ysebaert SA, Франция).…”
Section: объекты и методы исследованияunclassified
“…In the field of process monitoring and control, the Sensing Lab has developed different studies at laboratory and industrial scale by applying NIR sensors, doing the groundwork in bridging the gap between NIRS potentials and its actual implementation as Process Analytical Technology tool in the food industry. 8 The studies cover beer 9 and wine 10 fermentation, milk coagulation, [11][12][13] and grain milling. 14…”
Section: Evaluation Of Food Quality and Shelf Lifementioning
confidence: 99%