2020
DOI: 10.1007/s00784-020-03640-7
|View full text |Cite
|
Sign up to set email alerts
|

Effect of restorative timing on shear bond strength of composite resin/calcium silicate–based cements adhesive interfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
41
0
4

Year Published

2021
2021
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(48 citation statements)
references
References 37 publications
3
41
0
4
Order By: Relevance
“…Biodentine TM (Septodont, Saint-Maur-des-Fossés Cedex, France, BD) is such a calcium silicate cement with favorable properties (e.g., antibacterial activity [23], biocompatibility [24,25]). The technique of immediate adhesive restoration after placement and setting of BD (12 min [26]), as applied in group 1 of the current study, is supported in recent literature [27,28]. Considering the direct application of dental adhesives on residual carious dentin after SCT in deep cavities, conflicting results with regard to the influence on pulpal cells are existing [29][30][31].…”
Section: Introductionsupporting
confidence: 56%
“…Biodentine TM (Septodont, Saint-Maur-des-Fossés Cedex, France, BD) is such a calcium silicate cement with favorable properties (e.g., antibacterial activity [23], biocompatibility [24,25]). The technique of immediate adhesive restoration after placement and setting of BD (12 min [26]), as applied in group 1 of the current study, is supported in recent literature [27,28]. Considering the direct application of dental adhesives on residual carious dentin after SCT in deep cavities, conflicting results with regard to the influence on pulpal cells are existing [29][30][31].…”
Section: Introductionsupporting
confidence: 56%
“…According to the American Association of Endodontists, to achieve a good coronal seal, a 3-4 mm layer of glass-ionomer should cover the MTA, followed by bonded resin restoration [53]. In fact, it is worth mentioning that recent research revealed a higher shear bond strength value between calcium silicate-based cement (such as Biodentine and MTA) overlaid with resinbased composite than glass ionomer [138][139][140][141]. According to Meraji et al [140], placing the glass ionomer cement over the capping material is not recommended.…”
Section: Discussionmentioning
confidence: 99%
“…Synthetic bioceramics were developed in recent years to offset the drawbacks of naturally sourced materials such as MTA [17][18][19][20][21][22][23]. Biodentine is composed of tricalcium silicate, calcium carbonate and zirconium oxide.…”
Section: Antimicrobialmentioning
confidence: 99%