2020
DOI: 10.1016/j.asr.2020.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Effect of selection of combined observations on cycle-slip repair success rate for BDS triple-frequency signals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…Since the BDS heterogeneous constellation includes Geosynchronous Earth Orbit (GEO) satellites, Inclined Geosynchronous Satellite Orbit (IGSO) satellites, and Middle Earth Orbit (MEO) satellites, using the same threshold for different types of satellites will result in missing or misjudging the number of anomaly satellite signals. It is recommended that the detection threshold could be selected between 0.01 and 0.02 m during moderate geomagnetic storms [ 32 , 33 , 34 , 35 , 36 ]. Then, we calculated the PAS index for all the BDS stations globally.…”
Section: Resultsmentioning
confidence: 99%
“…Since the BDS heterogeneous constellation includes Geosynchronous Earth Orbit (GEO) satellites, Inclined Geosynchronous Satellite Orbit (IGSO) satellites, and Middle Earth Orbit (MEO) satellites, using the same threshold for different types of satellites will result in missing or misjudging the number of anomaly satellite signals. It is recommended that the detection threshold could be selected between 0.01 and 0.02 m during moderate geomagnetic storms [ 32 , 33 , 34 , 35 , 36 ]. Then, we calculated the PAS index for all the BDS stations globally.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, they are selected as the optimal GF-phase combination coefficients for B1I/B3I/B2a and B1C/B3I/B2a signals to detect and repair cycle slips. Yao et al (2020) indicated that the form of two EWL combinations for 2EWL&1GF does not affect The MTIV value of GF-phase combinations within 100  cycles. Cycle slip repair success rate for 2EWL&1GF-phase combination based on BDS-3.…”
Section: Gf-phase Combinationsmentioning
confidence: 96%
“…This paper uses the Maximum Threshold of Ionospheric Variation (MTIV), (Yao et al, 2020) which demonstrates the four times STD of the residual ionosphere to evaluate the performance on the GF-phase combination detecting the insensitive cycle slip group ΔN 1 =ΔN 2 =ΔN 3 and analyze the detection effect of different GF-phase combinations. Table 3 displays the relevant parameters of the BDS-3 GF-phase combination within 5  cycles, and Figure 3 shows the MTIV value of the corresponding GF-phase combination within 100  cycles.…”
Section: Gf-phase Combinationsmentioning
confidence: 99%
See 2 more Smart Citations