2018 IEEE Electrical Insulation Conference (EIC) 2018
DOI: 10.1109/eic.2018.8481129
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Stress Grading Tape Conductivity on the Electric Field Distribution in Stress Grading System of an Inverter-Fed Rotating Machine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 8 publications
0
10
0
Order By: Relevance
“…Nonlinear resistance tapes are the universal choice for stress-grading motor and generator coils [ 21 ]. Evaluating system performance by simulating the electric field and potential distributions in the overhang region showed that a highly conductive stress-grading tape reduces the maximum electric field at this region [ 40 ]. Usually, the main insulation is provided with outer corona protection applied by multilayer semiconducting paints or wrapping tapes [ 28 ].…”
Section: Electric-field Grading In Hv Applicationsmentioning
confidence: 99%
See 3 more Smart Citations
“…Nonlinear resistance tapes are the universal choice for stress-grading motor and generator coils [ 21 ]. Evaluating system performance by simulating the electric field and potential distributions in the overhang region showed that a highly conductive stress-grading tape reduces the maximum electric field at this region [ 40 ]. Usually, the main insulation is provided with outer corona protection applied by multilayer semiconducting paints or wrapping tapes [ 28 ].…”
Section: Electric-field Grading In Hv Applicationsmentioning
confidence: 99%
“…Naeini et al [ 40 ] simulated the effect of tape conductivity on the electric field distribution in a stress-grading system of an inverter-fed rotating machine. The main parts of this system consisted of a semiconductive armor tape (CAT) and a stress-grading tape (SGT).…”
Section: Current Applications Of Nonlinear Polymer Composites In Hv Engineeringmentioning
confidence: 99%
See 2 more Smart Citations
“…Conductive armor tape (CAT) is wound on the outside of the insulation tape to prevent partial discharge (PD) between the grounded slot's inner surface and the coil. The CAT promotes complete grounding of the outermost coil even under the condition of point contact between the slot and the coil [2]- [5]. The CAT is applied to the entire area of the straight part of the coil and extended to the beginning of the overhang region.…”
Section: Introductionmentioning