2017
DOI: 10.1007/s11223-017-9862-8
|View full text |Cite
|
Sign up to set email alerts
|

Effect of the Electrodynamic Treatment on the Life of AMg6 Aluminum Alloy Weld Joints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 2 publications
0
2
0
1
Order By: Relevance
“…The analysis of results of evaluation of change in values of the temperature of surface of plates T surf under the inductors L (Figure 1, a) at TPEMF, as well as in the zone of contact interaction of the electrode 2 ( Figure 1, b) in the EDT zone, showed influence of Joule heating on the stressed state of specimens at the methods of treatment described above is almost absent. Thus, the peak values of T surf at TPEMF did not exceed 25 °C [8], while at EDT -30 °C [11], which has no significant influence on the stressed state of AMg6 alloy [10].…”
Section: Scientific and Technicalmentioning
confidence: 99%
See 1 more Smart Citation
“…The analysis of results of evaluation of change in values of the temperature of surface of plates T surf under the inductors L (Figure 1, a) at TPEMF, as well as in the zone of contact interaction of the electrode 2 ( Figure 1, b) in the EDT zone, showed influence of Joule heating on the stressed state of specimens at the methods of treatment described above is almost absent. Thus, the peak values of T surf at TPEMF did not exceed 25 °C [8], while at EDT -30 °C [11], which has no significant influence on the stressed state of AMg6 alloy [10].…”
Section: Scientific and Technicalmentioning
confidence: 99%
“…The interaction of magnetic field of the inductor and the eddy currents induced by it in the disc 3 results in generation of electrodynamic force, which transfers pressure P EDT through the electrode 2 to the contact area simultaneously with passing of pulsed current through it. The commutation of electric circuit consisting of capacity, inductance of the inductor and active resistance of the conductors, was realized by the control key K. The EDT was performed at the values of U ch = 500 V and C ch = 6600 mF and were, respectively, 3.1 kA and 1.0 ms [10]. The effect of EDT, as well as in the case of TPEMF, is determined by summing the two effects, the first of which is the pulsed pressure P EDT preset by passing PEC through the inductor L, disc 3 and electrode 2, the value of which reaches 20 kN at U ch = 500 V. The second is the electric current of a specified density which spreads from the contact area.…”
mentioning
confidence: 99%
“…В той же час, експериментальний метод оцінки ефективності ЕДО, який описано в роботі [6], достатньо складно використовувати для пошуку оптимальних режимів обробки широкої гами металів, сплавів і зварних з'єднань. Це пов'язано із розглядом і оцінкою великої кількості технологічних варіантів ЕДО на відповідність встановленому критерію оптимізації -зниженню залишкових зварювальних напружень до заданого рівня.…”