2021
DOI: 10.1016/j.cattod.2020.02.037
|View full text |Cite
|
Sign up to set email alerts
|

Effect of UV-A-assisted iron-based and UV-C-driven oxidation processes on organic matter and antibiotic resistance removal in tertiary treated urban wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(22 citation statements)
references
References 56 publications
0
19
0
Order By: Relevance
“…UV-C driven SR-AOPs have been studied for the degradation of different contaminants and for the inactivation of several pathogens, but only few studies involve the use of complex matrices [ 14 , 15 , 31 , 32 , 33 ]. Mahdi-Ahmed et al (2014) reported Ciprofloxacin (CIP) oxidation by UV-based AOPs, comparing the performances of three oxidants, PMS, PS, and H 2 O 2 in DW and UWW.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…UV-C driven SR-AOPs have been studied for the degradation of different contaminants and for the inactivation of several pathogens, but only few studies involve the use of complex matrices [ 14 , 15 , 31 , 32 , 33 ]. Mahdi-Ahmed et al (2014) reported Ciprofloxacin (CIP) oxidation by UV-based AOPs, comparing the performances of three oxidants, PMS, PS, and H 2 O 2 in DW and UWW.…”
Section: Resultsmentioning
confidence: 99%
“…in UWW by PMS (1 mmol/L)/UV-C radiation. The high oxidant concentration used in the present work was selected considering previous studies [ 32 , 35 , 36 ]. Arslan-Alanton et al (2021) could not detect quantifiable DNA for the genes 16S rRNA , aphA and tetA as a result of the application of PMS/UV-C treatment at a concentration of 2 mmol/L of oxidant in tertiary treated UWW [ 32 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…130 A recent article reported that using UVC-driven PC can effectively inactivate ampicillin-, kanamycin-, and tetracycline-resistant multi-drug-resistant E. coli (>6.5 log) (an initial concentration of 8 log) within 80 min, and can effectively remove aphA (kanamycin resistance gene) and tetA (tetracycline resistance gene) (>3.0 log) (an initial concentration of 8 log) within 80 min. 92 PEC is an improved advanced oxidation processes based on PC; it applies a potential bias to timely remove the photogenerated electrons, suppressing the recombination of photoelectrons with photoholes. 131,132 This leads to a longer lifetime of the charge and therefore improves the photocatalytic activity.…”
Section: Advances In Water Disinfection Technologies In Removing Arb ...mentioning
confidence: 99%