1999
DOI: 10.1016/s0889-5406(99)70246-5
|View full text |Cite
|
Sign up to set email alerts
|

Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
64
1
5

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 91 publications
(74 citation statements)
references
References 8 publications
4
64
1
5
Order By: Relevance
“…3,10,15 Variation of facial crown contour may also be a contributing factor. 16,17 All teeth in this study had mean in-out values that were significantly lower than Andrews' original findings, but the relative crown prominence follows a pattern similar to that seen in Andrews' study, a point of considerable importance.…”
Section: In-out or Crown Prominencesupporting
confidence: 59%
See 1 more Smart Citation
“…3,10,15 Variation of facial crown contour may also be a contributing factor. 16,17 All teeth in this study had mean in-out values that were significantly lower than Andrews' original findings, but the relative crown prominence follows a pattern similar to that seen in Andrews' study, a point of considerable importance.…”
Section: In-out or Crown Prominencesupporting
confidence: 59%
“…16,17 Of particular clinical importance is the posttreatment torque measurement for maxillary central incisors. Torque of the upper incisors is an important factor in establishing the smile line, proper anterior guidance, and class I relationship of the teeth because anterior teeth with deficient torque tend to prevent the distal movement of the anterior maxillary segment.…”
mentioning
confidence: 99%
“…Therefore, optimal treatment outcomes require effective torque expression, which is sensitive to irregularities in tooth anatomy, the size, morphology, and engagement of the archwire in the bracket, as well as the position, material properties, and slot size of the bracket (11)(12)(13)(14)(15)(16)(17). For example, although 0.22-inch brackets might be outperform 0.018-inch in some clinical aspects like sliding mechanics, they are inferior in torque expression (18,19).…”
Section: Introductionmentioning
confidence: 99%
“…However, torque expression is a result of the interaction of many factors: bracket design (12), wire / slot play (engagement angle) (12), mode of ligation, 12 bracket deformation (13), wire stiffness (12,14), magnitude of wire torsion and dimension (13,(15)(16)(17), and wire edge beveling (18)(19)(20)(21)(22). Clinical factors such as initial tooth inclination13 bracket position (14,23), and tooth anatomy (24)(25)(26)(27) are also determinants of torque expression.…”
Section: Introductionmentioning
confidence: 99%