Abstract: The purpose of this study was to evaluate the safety and efficacy of the new 8 Fr guide catheter-compatible Flexicut directional atherectomy device and to compare it with the conventional Atherocath GTO catheter. The 6 Fr Flexicut catheter has a larger cutting window and a titanium nitride-coated cutter to effect more tissue removal as well as treat mildly calcified lesions. A group of 143 lesions in 117 consecutive patients treated with the Flexicut catheter in four centers were compared with a control group … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…1) Several devices such as those used in directional coronary atherectomy, 6) RA, [7][8][9][10][11] and cutting balloon [10][11][12] for calcified lesions have been proposed to achieve optimal dilation prior to stent implantation. However, it is occasionally difficult to achieve dilation because of the presence of a heavy calcified plaque even after RA.…”
Section: Discussionmentioning
confidence: 99%
“…1) Several devices such as those used in directional coronary atherectomy, 6) RA, [7][8][9][10][11] and cutting balloon [10][11][12] for calcified lesions have been proposed to achieve optimal dilation prior to stent implantation. However, it is occasionally difficult to achieve dilation because of the presence of a heavy calcified plaque even after RA.…”
Section: Discussionmentioning
confidence: 99%
“…[1][2][3][4] In these kinds of lesions, the removal of plaque potentially enhances the immediate procedural success by reducing plaque shift, which is responsible for side branch closure or vessel compromise. 5 In patient 1 we regarded plaque excision as the preferred treatment because both balloon angioplasty and stenting presented a very high risk of jeopardising the ostium of the left anterior descending artery, the mid left circumflex, or both. The bifurcation lesion of the crux obviously could have been treated with elective stent implantation.…”
Section: Discussionmentioning
confidence: 99%
“…One of the new designs is compatible with six French delivery systems 3 . Plaque removal can also reduce plaque shift and improve outcome, as indicated by a consecutive series with directional coronary atherectomy often using eight French compatible devices 35 . Still the role of this technique in the drug eluting stents era is questionable.…”
mentioning
confidence: 99%