2021
DOI: 10.1002/eqe.3437
|View full text |Cite
|
Sign up to set email alerts
|

Effects and dynamic characteristics of the core‐suspended isolation system assessed by long‐term structural health monitoring

Abstract: The seismic isolation mechanism of the core‐suspended isolation (CSI) system comprises a double layer of inclined rubber bearings installed on top of a reinforced core structure. A multilevel structure is then suspended from a hat truss or umbrella girder constructed on the seismic isolation mechanism. The first building to use the CSI system was the Safety and Security Center in Tokyo, Japan, whose structural health monitoring system has detected and recorded 231 earthquake motions since 2006, including the 2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 23 publications
0
4
0
1
Order By: Relevance
“…Similarly, z * i (ω) is the complex conjugate term of z i (ω) and z * i (ω) = z i (−ω). Substituting the expression of the frequency-domain solution of complex mode z i (ω), i.e., Equation (8), into Equation ( 13), the PSDF of the structural response can be expressed as:…”
Section: Quadratic Decomposition Of the Psdf Of Dynamic Responsesmentioning
confidence: 99%
See 1 more Smart Citation
“…Similarly, z * i (ω) is the complex conjugate term of z i (ω) and z * i (ω) = z i (−ω). Substituting the expression of the frequency-domain solution of complex mode z i (ω), i.e., Equation (8), into Equation ( 13), the PSDF of the structural response can be expressed as:…”
Section: Quadratic Decomposition Of the Psdf Of Dynamic Responsesmentioning
confidence: 99%
“…Combined with the characteristics of suspension structures, the structural vibration was reduced with the arrangement of rocking walls and connection damping. A novel CSI vibration isolation system, made of double-layer inclined rubber bearings and installed on top of the core frame, was also proposed by Saruta et al [7], and its good seismic performance was confirmed by shaking table tests and long-term structural health monitoring [8]. The seismic responses of suspension buildings with viscous dampers under 20 ground motion time-history curves were analyzed in previous research [9], and the results indicated that the structural response was affected by the arrangement of dampers and the inter-layer stiffness.…”
Section: Introductionmentioning
confidence: 99%
“…El monitoreo de salud estructural (SHM) es un sistema que puede monitorear el movimiento estructural de un edificio durante cargas externas como terremotos (Ren, 2020). Las vibraciones del sistema de aislamiento sísmico de núcleo suspendido (CSI) se utiliza para la seguridad y protección del edificio, cuyo sistema de vigilancia de la salud estructural (SHM) detecta y registra movimiento sísmico (Nakamura & Okada, 2021). La vida eficaz de los edificios convencionales a gran escala por lo regular se decreta en cientos de años, mientras que la vida útil de los propios sensores del sistema de monitoreo de salud estructural (SHM) solo se puede mantener en más de diez años o incluso menos, lo cual es muy importante y significativo que se identifique, detecte de manera oportuna y efectiva las fallas de los sensores en el sistema SHM del edificio .…”
Section: Introduccionunclassified
“…NDE and SHM techniques, thereby preventing catastrophic structural failure. In the past decades, various NDE and SHM approaches have been proposed and applied to civil engineering structures to ensure structural safety [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%