2020
DOI: 10.3349/ymj.2020.61.8.689
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Air Purifiers on Patients with Allergic Rhinitis: a Multicenter, Randomized, Double-Blind, and Placebo-Controlled Study

Abstract: Purpose Exposure to particulate matter (PM) is a well-known risk factor in the triggering and exacerbation of allergic airway disease. Indoor environments, where people spend most of their time, are of utmost importance. To assess the effects of air purifiers [equipped with high-efficiency particulate air (HEPA) filters] on allergic rhinitis (AR) in adult patients, we performed a multicenter, randomized, double-blind, and placebo-controlled study. Materials and Methods … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
27
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(29 citation statements)
references
References 30 publications
1
27
1
Order By: Relevance
“…44 adults with allergic rhinitis in two cities in South Korea found 53.2% and 30.7% decreases on average in bedroom and living room PM 10 , respectively, using a repeated measures approach. 100 Mean baseline PM 10 in this study was 33.4 (5.6) μg/m 3 in the bedrooms We observed no meaningful change in endotoxin loadings in homes assigned to the HEPA vs. control families. From baseline to follow-up, geometric mean EDC endotoxin dropped 20% in HEPA homes and 29% in control homes, but the HEPA vs. control group difference was not statistically significant.…”
Section: Discussioncontrasting
confidence: 55%
“…44 adults with allergic rhinitis in two cities in South Korea found 53.2% and 30.7% decreases on average in bedroom and living room PM 10 , respectively, using a repeated measures approach. 100 Mean baseline PM 10 in this study was 33.4 (5.6) μg/m 3 in the bedrooms We observed no meaningful change in endotoxin loadings in homes assigned to the HEPA vs. control families. From baseline to follow-up, geometric mean EDC endotoxin dropped 20% in HEPA homes and 29% in control homes, but the HEPA vs. control group difference was not statistically significant.…”
Section: Discussioncontrasting
confidence: 55%
“…Despite the use of HEPA air purifiers in previous studies to assess their effect on HDM, 39 , 40 , 50 dog 48 , 61 , 62 , 63 and cat 34 , 39 , 48 , 61 , 62 , 63 , 64 allergen exposure, these were either restricted to one 34 , 39 , 61 , 64 or two allergens, 37 , 38 , 62 , 63 based on one home only 50 or did not measure airborne allergen levels. 37 , 38 , 62 , 63 , 64 For instance, Jia‐Ying et al.…”
Section: Discussionmentioning
confidence: 99%
“…Despite the use of HEPA air purifiers in previous studies to assess their effect on HDM, 39 , 40 , 50 dog 48 , 61 , 62 , 63 and cat 34 , 39 , 48 , 61 , 62 , 63 , 64 allergen exposure, these were either restricted to one 34 , 39 , 61 , 64 or two allergens, 37 , 38 , 62 , 63 based on one home only 50 or did not measure airborne allergen levels. 37 , 38 , 62 , 63 , 64 For instance, Jia‐Ying et al. 40 showed a decrease in HDM allergens similar to the percentage reported in our study, but analyzing bedding and static dust samples (68.3% and 71.0%) and not airborne samples.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the microorganisms on the lter will multiply, die or decompose, so the method above cannot directly re ect the microbial aerosols. Some scholars [23][24][25][26][27] have con rmed that air puri ers can effectively reduce the concentration of allergens in indoor air, thereby improving the clinical manifestations of patients with allergic rhinitis, and signi cantly reducing the drug needs. Some scholars [28] have proved that the air puri er has the effect of reducing the total colony number of the culture medium through the method of air sampling and fungus culture in the medium, but it has not been tested for bacterial species, and the puri cation of each microorganism cannot be seen directly.…”
Section: Introductionmentioning
confidence: 99%