Effects of Implant Stiffness, Shape, and Medialization Depth on the Acoustic Outcomes of Medialization Laryngoplasty

Abstract: Objective Medialization laryngoplasty is commonly used to treat glottic insufficiency. In this study, we investigated the effects of implant stiffness (Young’s modulus), medialization depth, and implant medial surface shape on acoustic outcomes. Study Design Basic science study using ex vivo laryngeal phonation model. Methods In an ex vivo human larynx phonation model, bilateral medialization laryngoplasties were performed with implants of varying stiffness, medial surface shape (rectangular, divergent and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
23
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 24 publications
1
23
0
Order By: Relevance
“…Its stiffness was previously measured using an instrumented indentation system . The softer implants were made by combining the two components of a silicone liquid polymer (Ecoflex 0030; Smooth On Inc, Easton, Pennsylvania) with a silicone thinner solution at different ratios to achieve varying degrees of stiffness as previously published . The two silicone components and the thinner solution were combined at a ratio of 1:1:1 (21.6 kPa, I2), 1:1:2 (9.3 kPa, I3), and 1:1:3 (5.5 kPa, I4) (Table ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Its stiffness was previously measured using an instrumented indentation system . The softer implants were made by combining the two components of a silicone liquid polymer (Ecoflex 0030; Smooth On Inc, Easton, Pennsylvania) with a silicone thinner solution at different ratios to achieve varying degrees of stiffness as previously published . The two silicone components and the thinner solution were combined at a ratio of 1:1:1 (21.6 kPa, I2), 1:1:2 (9.3 kPa, I3), and 1:1:3 (5.5 kPa, I4) (Table ).…”
Section: Methodsmentioning
confidence: 99%
“…During medialization thyroplasty, both glottal contour and vocal fold body stiffness are altered concurrently by the implant shape and stiffness. However, the roles of implant stiffness and medial surface shape in optimizing phonation remain unclear and unexplored . The difficulty in visualizing the medial surface shape and measuring tissue stiffness in vivo has contributed to a poor understanding of these parameters and their effects.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Because phonation is a dynamic process dependent on the appropriate production of a mucosal wave propagating from the conus elasticus through the free edge of the true VF, we hypothesize that investigation regarding the viscoelastic VF properties have substantive clinical relevance. Despite intense interest in the varying viscosities of compounds used in injection medialization laryngoplasty, only one review and a single study investigated the effects of implant stiffness on dynamic outcomes following medialization . In that study, Zhang et al investigated the effect of three silicone implants of varying rigidity on acoustic function in excised human VFs …”
Section: Introductionmentioning
confidence: 99%
“…Despite intense interest in the varying viscosities of compounds used in injection medialization laryngoplasty, only one review and a single study investigated the effects of implant stiffness on dynamic outcomes following medialization . In that study, Zhang et al investigated the effect of three silicone implants of varying rigidity on acoustic function in excised human VFs …”
Section: Introductionmentioning
confidence: 99%